Ground screw testing in Calne
JustBases offers standalone ground screw testing in Calne: upward pull-out, downward compression and sideways lateral tests. We can discuss a trial installation or suitable existing screws, including those supplied or fitted by another company, and quote the testing and reporting your project needs.
Ground screw tests we offer
A physical test applies a controlled force and records how the selected screw responds. The direction matters: a result obtained by pulling up answers a different question from pushing down or loading sideways. We agree the method with the people responsible for the foundation requirement.
Pull-out testing
An upward force is applied to investigate resistance to uplift. The readings describe the response of the tested screw under the agreed loading, giving the project team evidence for the upward-force requirement it has identified.
Learn more: Pull-out testingCompression testing
A direct compression test pushes downward and measures the response under that load. It provides physical downward-loading evidence. Where an applicable calculation from pull results is agreed instead, we identify it as calculated evidence, not a direct compression test.
Learn more: Compression testingLateral testing
Sideways loading is used to investigate horizontal response. The relevant direction, position and load are agreed for the foundation question, with a setup that can apply and react against that force safely.
Learn more: Lateral testingGround screw testing prices in Calne
The guide fees below distinguish the three physical test methods. The written quote reflects the required work, number and location of points, safe setup, access, travel and agreed reporting and calculations. Tell us whether you are considering a trial or need evidence from an existing foundation.
Installation torque monitoring records resistance to turning while the screw is being installed. A specialist torsional load test applies a separate twisting action. Both are price on application and booked within their own agreed scope, not automatically included with a physical test. Neither should be described as a direct pull, compression or lateral result.
Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.
- Pull test (tensile or uplift test)
- From £505
- Load test (compression test)
- From £1,010
- Lateral test (sideways load)
- From £495
- Installation torque monitoring
- Price on application
- Specialist torsional load test
- Price on application
Each additional test
Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.
- Pull test (tensile or uplift test)
- £160 extra
- Load test (compression test)
- £320 extra
- Lateral test (sideways load)
- £155 extra
No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.
Ask about a ground screw test
Explain what you need to decide or what your project team has asked you to obtain. Add the Calne-area postcode, and say whether screws are planned, newly fitted or already supporting something.
You can send an existing test request, product information or photographs if handy. If the requirement is still taking shape, Craig can discuss what needs clarifying before a suitable test programme and written price are agreed.
Request your free quote
Give us your contact details and a short description of the testing you need. You can ask before the technical requirements are complete.
Your enquiry
Ground screw testing in Calne
How ground screw testing works
The work is arranged around the evidence required, with loading and safe arrangements settled before attendance. This gives the people using the findings a clear basis for understanding the test.
Define the evidence needed
We establish the purpose, selected positions and direction of force. The responsible designer or assessor identifies the required loading and acceptance criteria. Any requested project-specific calculations form part of the agreed quotation rather than an assumed complete design service.
Prepare and carry out the test
The tester checks the practical connection and working arrangement for the selected screw. Once the agreed setup is safe and ready, the test applies the specified loading and records the response. Connected structures and other site work must be accounted for in the arrangements.
Supply the agreed findings
You receive recorded results, a written report and the project-specific load calculations included in the quotation. The report makes clear the basis of the findings so the responsible project team can use them for its assessment.
Testing existing screws and trial installations
An early trial can help resolve a foundation choice while the proposed installation is still being developed. The project team agrees what is to be trialled and where, with a screw and installation arrangement relevant to the question. Tell us if you also need the trial screw installed so that responsibility is included in the scope.
For a fitted foundation, we first discuss what is being supported and whether the required test can be carried out safely. Screws installed by another company are welcome for assessment; available product and installation information helps establish what can be tested and how the result will be used.
Where a screw is connected to a building, opening up, unloading or temporary support may need to be arranged by the responsible competent people before testing. Leave structural fixings in place for the initial enquiry. Safe photographs and a description let us begin without asking you to dismantle the foundation.
What your test report tells you
The written report provides the findings for the work commissioned, alongside the recorded results and agreed project-specific load calculations. It explains the loading carried out and the screw’s measured response, allowing the responsible assessor to compare the evidence with the project requirement. Any limitation affecting that interpretation needs to remain clear.
A compression figure calculated from pull results is useful only where the method is applicable and agreed for the screw and project. Its basis and assumptions need to be identified separately from a direct downward test. Testing at selected screws contributes to foundation assessment; it is not certification of the complete building or an automatic planning or building-control approval.
Arranging testing in Calne
Homeowners, building suppliers and contractors can all contact us about testing. It helps to say what stage the project has reached and who will use the findings. We can then discuss the necessary test scope and any site preparation before agreeing a visit, rather than requiring you to resolve the technical brief alone.
For new supports as well as testing, see ground screw installation in Calne. You can compare other foundation work on the Calne overview, including poured concrete bases, or see the Wiltshire service area. A testing enquiry does not require an installation order.
Areas we cover around Calne
We consider testing enquiries in Calne and the surrounding places listed here. Send the actual site postcode and locality with the purpose of the test so we can confirm the visit arrangements.
The Calne area includes SN11, with nearby enquiries in relevant parts of SN15, SN10, SN8 and SN4. Travel and the work required at the address are included in the agreed quotation.
Calne neighbourhoods
Calne town centre, Chilvester, Abberd, Quemerford, Beversbrook, Lansdowne Park and Bremhill View.
Derry Hill, Studley and nearby hamlets
Derry Hill, Old Derry Hill, Studley, Sandy Lane, Bowood, Whetham, Mile Elm and Ratford.
Bremhill and the Tythertons
Bremhill, Bremhill Wick, East Tytherton, Tytherton Lucas, Foxham, Charlcutt, Spirthill, Stanley, Avon and Dumb Post.
Hilmarton and surrounding settlements
Hilmarton, Goatacre, Highway, New Zealand, Corton, Littlecote, Catcombe and Clevancy.
Cherhill, Calstone and Heddington
Cherhill, Yatesbury, Lower Compton, Blackland, Calstone Wellington, Stockley, Heddington, Heddington Wick, Broad’s Green and the Splatts.
Bromham and neighbouring places
Bromham, St Edith’s Marsh, Westbrook, Hawkstreet, Netherstreet, Chittoe and Bishop’s Cannings.
Avebury and the wider village area
Avebury, Avebury Trusloe, Beckhampton, West Kennett, Berwick Bassett, Winterbourne Monkton, Winterbourne Bassett, Broad Hinton, Uffcott and Lyneham.
Feedback on Craig’s earlier work
Feedback on Craig’s earlier groundwork and customer service.
"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
Frequently asked questions
These questions explain how to begin, what the methods establish and how the work is agreed. You can ask about a project even if the final testing requirement has not yet been written.
Can I enquire before anyone has written a test specification?
Yes. Explain the project and why testing is being considered, with the site postcode. We can discuss the evidence needed and which questions require input from the responsible designer or assessor. The detailed method, loading and criteria must be settled before testing, but they are not a barrier to the first conversation.
Will you consider screws that another company installed?
Yes. We offer testing independently of installation, including suitable third-party foundations. Tell us what the screws support and share any product or installation details you already hold. The tester needs to assess the proposed connection and safe test arrangement before confirming what can be carried out.
How do I know which loading direction is required?
The foundation requirement determines the direction. Pull-out testing applies uplift, compression testing applies a downward force, and lateral testing applies force sideways. If the request simply says “load test”, share the request with us so the responsible project team can clarify which evidence it needs before a method is quoted.
What does a trial test involve before the main foundation is installed?
It uses the agreed trial screw and position to obtain evidence for a foundation decision. The arrangement needs to be relevant to what the designer is considering, including the product and installation conditions. Confirm whether installing the trial is part of the work requested or is being provided by your installer.
Can testing be considered beneath an existing building?
It can be discussed, but the building’s support and the test setup must be assessed first. Loading or disconnecting a structural support can affect what is above it. Any necessary opening, unloading or temporary support must be planned by competent people; do not loosen a connection just to provide photographs for an enquiry.
Who decides the test loads and what counts as an acceptable result?
The responsible designer or assessor sets the project’s test requirement and acceptance criteria. We agree the practical test arrangement and recorded information against that requirement. The agreed criteria establish how the recorded response will be judged.
Does pull-out testing measure downward compression?
Not directly. An upward test measures the response to the applied pull. Compression capacity may be calculated from pull data where an appropriate method is applicable and agreed, but that is a calculated conclusion with a stated basis. A direct compression test instead measures the screw while a downward force is physically applied.
When would lateral testing be useful?
It is relevant when the foundation assessment needs evidence of resistance or movement under horizontal force. The project team identifies the direction and positions to investigate. A lateral result concerns that agreed sideways loading and should be distinguished from the evidence obtained under upward or downward force.
Can installation torque monitoring be requested after the screw is already fitted?
Monitoring records turning resistance during installation, so it needs arranging while the screw is being driven. If no record was taken, a later visit cannot recreate that original measurement. Tell us what evidence is now needed and we can discuss whether a suitable physical test or another agreed assessment addresses it. Monitoring is price on application.
What is specialist torsional testing?
It applies an agreed twisting load to investigate rotational response. That is different from recording turning resistance during installation and different from loading a screw sideways. It is a separately arranged specialist service, price on application, with its own test purpose and safe setup.
What will JustBases supply after the test?
The commissioned service includes recorded results, a written report and the project-specific load calculations agreed in the quotation. The documents distinguish measured test evidence from calculations. If your project has a particular information requirement, share it when arranging the scope so the proposed deliverables can be confirmed.
Does a test report approve the complete foundation or building?
No. It supplies evidence from the agreed testing for the responsible project team to assess. The complete foundation and building still need the appropriate design and any necessary approvals, taking account of more than the selected test points. The testing quotation does not automatically include a whole-building design or approval service.
What if there is limited room around the proposed screw?
Tell us what surrounds the point and how it can be reached. The tester needs enough suitable space for the connection and the arrangement that applies and reacts against the load. We review that before attendance; if the requested setup is impractical, the relevant team must agree a suitable way forward.
What affects the final price and booking arrangements?
The method, number of points, site access, preparation, travel and agreed reporting or calculations all contribute to the quoted scope. Let us know about the project programme so we can discuss a workable visit. You will receive the written work and price to consider before a booking is confirmed.
What does each additional ground screw test cost?
At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type. The first test of each type is priced separately, using the starting price for your location. The extra-test charges stay the same in every location.
Discuss the testing your project needs
Request a ground screw testing quote, call Craig on 01202 039753 or use WhatsApp. Start with where the site is and the decision the test needs to help with; existing documents can be added if available.