Detail of an installed ground screw

Ground screw testing in Chard

We offer standalone ground screw testing in Chard, including suitable trial screws and existing foundations installed by others. Pull-out, compression and lateral testing address different loading requirements. Tell us why the evidence is needed and the postcode; the results, written report and project-specific load calculations are agreed in the quotation.

Ground screw tests we offer

Choose the test around the foundation question that needs answering. The responsible designer or assessor identifies the required loading and acceptance criteria, and we agree the testing scope before attendance. You can contact us while that requirement is still being developed.

Pull-out testing

An upward load assesses resistance to uplift and records the screw’s response under the agreed method. It can provide evidence relevant to supports designed to resist lifting forces. The required load and criteria are project-specific.

Learn more: Pull-out testing

Compression testing

A direct compression test applies downward loading and measures the response. Where an applicable agreed calculation instead derives compression evidence from a pull-out test, the report must identify that basis and its assumptions. Make clear if direct measurement is required.

Learn more: Compression testing

Lateral testing

A sideways load assesses the response in the agreed lateral direction. This addresses a different force from uplift or downward loading and needs its own suitable setup and criteria. The foundation’s design requirement determines which direction or directions matter.

Learn more: Lateral testing

Ground screw testing prices in Chard

The testing guides below provide a starting point. The quotation confirms the methods, positions and practical work being commissioned, together with the written report and agreed project-specific load calculations. Tell us if a trial installation or other preparation also needs arranging.

Installation torque monitoring records the resistance to turning as a screw is installed. Specialist torsional testing separately applies a twisting load. Each service is price on application, and neither is automatically included with physical testing or an installation. They should be requested as distinct scopes rather than treated as substitutes for every load test.

Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.

Installation torque monitoring
Price on application
Specialist torsional load test
Price on application

Each additional test

Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.

Pull test (tensile or uplift test)
£160 extra
Load test (compression test)
£320 extra
Lateral test (sideways load)
£155 extra

No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.

Ask about a ground screw test

Begin with the reason for the test and site postcode. You may need evidence for a planned foundation, an installed system or a request from your building supplier or assessor. Let us know which applies; a complete test specification is not required to make contact.

Use the form, call 01202 039753 or use WhatsApp. Send any existing request, product information or photos when available. We will identify the further decisions needed for a useful, safely arranged test.

Request your free quote

Give us your contact details and a short description of the testing you need. You can ask before the technical requirements are complete.

Your enquiry

Ground screw testing in Chard

Please provide either an email address or a phone number.

Add site photos, video or a drawing (optional)

Upload up to 5 photos or a short video of your site to help us provide an accurate quote.

0/5 files. JPG, PNG, WebP, PDF, MP4, MOV accepted — up to 100MB each.

Free, no-obligation quote. Your details are used to respond to this enquiry; see our privacy policy.

How ground screw testing works

The aim is to produce evidence that answers the agreed foundation requirement. That needs a defined test and a suitable practical setup as well as a visit to site.

Establish the testing requirement

We discuss the purpose and the available screw or foundation information. Before testing, the responsible assessor’s requirements establish the relevant positions, loading and criteria. The quotation defines our testing and calculation work and any preparation that must precede it.

Agree safe setup and carry out the work

The chosen method needs suitable access to the test position and safe arrangements for applying load. Existing building loads and connections are assessed where relevant. Testing follows the agreed scope, recording the applied loading and response without treating an unrelated direction as equivalent evidence.

Provide results and calculations

We provide recorded results and a written report, with project-specific load calculations as agreed in the quotation. The evidence identifies the work undertaken and the basis of any derived values, ready for assessment against the project’s requirements.

Testing existing screws and trial installations

For a proposed foundation, a trial needs to be arranged while its findings can still inform the work. Discuss the intended screw system and the decision the trial should support before choosing the test position. The responsible assessor can then establish how the trial is relevant to the proposed design.

For fitted screws, the first question is whether the requested loading can be applied safely to the actual foundation. A building already carried by the screws introduces existing loads and structural connections that need assessment. Any opening-up, unloading or temporary support must be planned and assigned to competent people before testing; keep those connections intact for the initial discussion.

Another installer’s foundation can be considered on the same basis. Tell us what is known about the system and what evidence has been requested. We can discuss feasibility and define the work without making a new installation purchase part of the testing enquiry.

What your test report tells you

Your written report and agreed project-specific load calculations provide the evidence commissioned in the quotation. They are for the foundation assessment, not an automatic approval of the building. The responsible designer or assessor decides what the findings demonstrate against the project requirements. If a separate design or approval service is needed, establish its scope as well as the testing.

Arranging testing in Chard

Tell us whether the screws are already fitted or are being planned. That allows the discussion to begin at the right stage, including coordination with an installer where monitoring or a trial is wanted. We confirm what needs agreeing before a testing date is booked.

For new foundation work, see ground screw installation in Chard. You can also compare Chard’s base services or check our Somerset service area. A testing-only enquiry is welcome.

Areas we cover around Chard

We welcome enquiries from Chard and the places below. TA20 is the main Chard district; adjoining enquiries include relevant parts of TA19 around Ilminster, EX13 around Chardstock and Membury, and EX14 around Stockland. Send the actual site postcode and village or neighbourhood so we can confirm arrangements for your address.

For the wider service area, see where we work in Somerset.

Chard neighbourhoods

Chard town centre, Avishayes, Combe, Crimchard, Holyrood, Jocelyn, Shepherd’s Lane and Furnham.

Combe St Nicholas and nearby hamlets

Combe St Nicholas, Wadeford, Nimmer, Cuttifords Door, Beetham, Clayhanger, Ham, Pudleigh, Sticklepath, Scrapton and Street Ash.

Chaffcombe and the Ilminster-side villages

Chaffcombe, Knowle St Giles, Cricket Malherbie, Donyatt, Dowlish Wake, Kingstone, Horton, Broadway and Ilminster.

Tatworth, Forton and South Chard

Tatworth, Forton, South Chard, Perry Street, Chard Junction, Chilson, Chilson Common and Yonder Hill.

Winsham and surrounding places

Winsham, Ammerham, Bridge, Leigh, Whatley, Street, Purtington, Cricket St Thomas and Cudworth.

Wambrook and the Blackdown villages

Wambrook, Higher Wambrook, Whitestaunton, Buckland St Mary, Birchwood, Blackwater, Blindmoor, Dommett, Newtown and Bishopswood.

Chardstock and nearby Devon villages

Chardstock, Tytherleigh, Bewley Down, Birchill, Burridge, Holy City, All Saints, Alston, Smallridge, Churchill, Coaxden, South Common, Colston, Waggs Plot, Membury, Yarcombe, Marsh and Stockland.

Thorncombe and neighbouring Dorset hamlets

Thorncombe, Holditch, Hewood and Synderford.

Feedback on Craig’s earlier work

Feedback on Craig’s earlier groundwork and customer service.

"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
— Verified CustomerMyBuilder · SO · Cobble edge and gravel strip
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
— Verified CustomerCheckatrade · BH20 · Garage base

Frequently asked questions

More on selecting evidence, existing foundations and what is included in a testing commission.

Can I ask about testing before I have a complete test brief?

Yes. Explain why you need evidence and give us the postcode. If an engineer, supplier or other assessor has requested it, share the request when available. We can discuss the available services and information still needed. The technical requirement must be agreed before testing, but an incomplete brief need not stop the first conversation.

How do I choose between pull-out, compression and lateral testing?

Start with the force the proposed foundation needs to resist. Pull-out concerns uplift, compression concerns downward load, and lateral testing concerns sideways load. The responsible designer or assessor establishes the evidence required for the project and any combination of directions. We agree a practical testing scope from that requirement; a result in one direction does not automatically establish the others.

Will you test screws installed by another company?

Yes, where the screws and site can be assessed and a suitable test arranged. Buying a JustBases installation is not a condition of enquiring. Product details, installation information and photos may help establish what can be tested, but tell us what you have rather than delaying contact to obtain a perfect set of records. The quote confirms the accepted work.

What is the purpose of testing a trial screw?

A trial can provide relevant load-response evidence before the final foundation installation is committed. The test position, screw product and intended use need to be chosen so that the evidence answers the design question. Tell us that this is a trial enquiry when you contact us, allowing the trial installation responsibilities and testing to be arranged together where required.

Can testing be carried out beneath an existing building?

Possibly, after assessing the foundation, its connections and the building loads already present. A safe setup may require planned access, unloading or temporary support by competent people. Leave structural connections intact while we discuss the work. If testing is suitable, the necessary preparation and responsibilities are agreed before it proceeds.

What will I receive after the test?

The commissioned deliverables are recorded results, a written report and project-specific load calculations as agreed in the quotation. The scope determines the testing and calculation work undertaken. This gives the responsible assessor evidence to use for the foundation question being addressed. A complete structural design for the building is not automatically included simply because a report has been commissioned.

Can compression evidence be calculated from a pull-out result?

Only where an applicable agreed method permits it and its assumptions suit the project. The calculated result must be identified as derived evidence, not described as a directly measured downward test. If direct compression evidence is required, that requirement needs to be made clear when the scope is agreed. We do not treat pull-out and compression as interchangeable measurements.

Who sets the test loads and the acceptance criteria?

The person responsible for the design or assessment establishes the project requirements. Those include the loading and response criteria needed to judge the result, and the relevant stopping arrangements. We agree how the specified requirement will be tested before attendance. If no criteria have been issued yet, say so at enquiry stage so that responsibility can be resolved before the work proceeds.

When should I request installation torque monitoring?

Request it while the screw installation is being arranged, so the specified turning-resistance record can be taken during driving. It is a separately agreed, price-on-application service rather than an automatic installation record. Tell us what your assessor expects to use it for; any relationship between those readings and capacity must use a justified method applicable to the product and project.

Is a torsional test the same as installation torque monitoring?

No. A specialist torsional test applies a separate twisting load to assess rotational response under an agreed method. Installation monitoring records resistance during insertion. They concern different operations and evidence, and both are separately price on application. A torque reading does not provide a universal conversion to pull-out, compression or lateral capacity; the project’s accepted method matters.

What space is needed around a test position?

There must be suitable access and a safe working arrangement for the loading method and the screw or connection being tested. The required setup is assessed for the actual position, so send a photo if convenient and mention fixed construction nearby. We will establish any necessary preparation with you. Do not remove a load-bearing connection just to make the head easier to photograph.

Does testing one screw prove every support is satisfactory?

No. The selected points and how their evidence will be used belong in the testing requirement. A result describes the tested arrangement and conditions; extending it to other supports needs an appropriate basis accepted by the responsible assessor. Agreeing the selection beforehand makes the work relevant without implying that one successful test automatically establishes the condition or capacity of the whole foundation.

What affects the testing quotation?

The physical methods, agreed test positions, practical setup and access all affect the work. The requested reporting and project-specific calculations also need to be identified. Any trial installation or preparation is included only where stated. We confirm the written scope before booking so the guide fee is not mistaken for an allowance for every possible test or related construction task.

Does the report certify the building or grant approval?

No. It supplies the agreed test evidence and calculation work for assessment. The building’s design, the suitability of its connections and other relevant compliance matters still need their appropriate professional or approval checks. A report is not automatic whole-building certification or Building Control approval, and the installation guarantee is not a warranty of a test result.

What does each additional ground screw test cost?

At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type. The first test of each type is priced separately, using the starting price for your location. The extra-test charges stay the same in every location.

Talk to Craig about the test you need

Use the testing enquiry form to explain the purpose and postcode. We will discuss the proposed work, settle the required scope and provide a written quotation before arranging the test.

You can also call 01202 039753 or use WhatsApp. Any technical request or photos you already have are useful, but you can ask the first question without them.