JustBases offers standalone ground screw testing in Gillingham, Dorset. We can discuss pull-out, compression and lateral tests on suitable trial screws or existing installations, including work by other installers, with the method and safe arrangements agreed for the site.

Ground screw tests we offer

Testing applies a load and records the response for the agreed question. Choosing the loading direction matters: evidence of uplift, downward support and sideways behaviour serves different purposes. If you are unsure which is required, explain why you have been asked for a test.

Pull-out testing

A pull-out test applies upward loading to investigate the screw’s response to uplift. The selected screw, loading arrangement and required criteria are agreed for the commission. It can provide evidence where the foundation needs to resist forces tending to lift the supported structure.

Learn more: Pull-out testing

Compression testing

A direct compression test applies downward loading and measures the response. It investigates support under that loading at the tested position. Where a compression assessment instead uses an applicable calculation method, that calculated evidence must be identified separately from a physically performed compression test.

Learn more: Compression testing

Lateral testing

Lateral testing applies sideways loading in the agreed direction. It is relevant to questions about horizontal resistance and movement, with the tested connection and loading arrangement considered as part of the scope. The result relates to that test rather than automatically establishing every direction of loading.

Learn more: Lateral testing

Ground screw testing prices in Gillingham

The guide distinguishes the physical testing options. The written price depends on the test being commissioned, the points and loading required, the practical setup and the agreed written results or calculations. Tell us the purpose first so we can establish a useful scope.

Installation torque monitoring and specialist torsional testing are separate, price-on-application services. Monitoring records resistance during screw insertion; torsional testing applies a twisting test. Neither is automatically included in a physical load-test booking or interchangeable with the other.

Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.

Installation torque monitoring
Price on application
Specialist torsional load test
Price on application

Each additional test

Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.

Pull test (tensile or uplift test)
£160 extra
Load test (compression test)
£320 extra
Lateral test (sideways load)
£155 extra

No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.

Ask about a ground screw test

You do not need to have bought installation from JustBases. Send the purpose and site postcode, saying whether the screws are already installed or are being considered for a trial. Any test request, installation record or photograph you have can help, but is optional for first contact.

Use the form, call 01202 039753 or send a WhatsApp message. We will clarify what needs to be established and what information is needed before the work can be agreed.

Request your free quote

Tell us where the screws are and what you need to find out.

Your enquiry

Ground screw testing in Gillingham (Dorset)

Please provide either an email address or a phone number.

Add site photos, video or a drawing (optional)

Upload up to 5 photos or a short video of your site to help us provide an accurate quote.

0/5 files. JPG, PNG, WebP, PDF, MP4, MOV accepted — up to 100MB each.

Free, no-obligation quote. Your details are used to respond to this enquiry; see our privacy policy.

How ground screw testing works

Agreeing the test

We establish the question the results need to answer, then agree the test method and intended positions. The required loads and acceptance criteria come from the responsible project or design requirements. Where these have not yet been set, we can explain what needs resolving before a test is commissioned.

Access and safe test arrangements

The proposed points must be accessible for a suitable loading and reaction arrangement. We assess the screw heads, connections and working space relevant to the intended test. Existing loads or an attached structure may affect what can safely be done, so keep connections intact while the arrangements are assessed.

Results and report

We supply recorded results and a written test report for the agreed testing. Project load calculations are provided where included in your quotation and supported by an applicable method. Physical measurements and calculated assessments are identified separately.

Testing existing screws and trial installations

If a foundation is already carrying a building, the first question is how the intended test can be undertaken safely. A photograph of the accessible head or connection, if you can obtain one safely, is useful for discussion. Do not loosen fixings, lift a floor or remove structural parts to make a test point available.

For a trial installation, agree which part of the work is being booked: providing or installing the trial screw, applying the test and what happens to the screw afterwards. That lets the test be arranged at a useful stage of the foundation planning, with the required evidence defined in advance.

What your test report tells you

Read the reported loading and response against the purpose agreed for the test. The evidence concerns the screw positions and arrangement tested. The responsible designer uses it with the building’s loads, connections and wider foundation requirements when deciding whether the proposal meets the required criteria. A test report does not by itself certify the whole building or approve every part of its foundation design.

If project load calculations are commissioned, their basis needs to suit the evidence and method being used. A calculated compression assessment should be described as calculated; a direct compression test produces measured downward-load evidence.

Arranging testing in Gillingham

Tell us where the work would take place and why testing is needed. We can then discuss the intended points, access and suitable scope before a visit is agreed. If the entrance differs from the site’s usual address, a short direction or location photograph can help us plan the arrival.

Areas we cover around Gillingham

We welcome enquiries across Gillingham centre, Peacemarsh, Lodbourne, Wyke, Ham, Newbury, Bay, Coldharbour, Westbrook, the Common Mead Lane area, Brickfields and Kingsmead. Nearby localities include Milton-on-Stour, Colesbrook, Bowridge Hill, Huntingford, Slaughtergate, Stock, Bugley, Eccliffe, Madjeston, the Langham Lane area, Shearstock and Sandley.

Around the town, you can also enquire from Bourton, Chaffeymoor, Silton, Buckhorn Weston, Kington Magna, Motcombe, East Stour, West Stour, Fifehead Magdalen, Stour Provost, Stour Row, Woodville, Todber, Marnhull, Stalbridge and Shaftesbury.

The adjoining enquiry area includes Mere, Zeals, West Knoyle, East Knoyle, Sedgehill, Semley, Kilmington, Stourton and Gasper in Wiltshire, and Cucklington, Stoke Trister, Bayford, Pen Selwood, Wincanton, Henstridge, Templecombe and Combe Throop in Somerset. Please send the actual address so we can confirm the work and travel arrangements.

Useful postcode districts in and around this area include SP8, SP7, BA12, BA9, BA8 and DT10. Please send your full postcode so we can confirm availability and quote for the actual site.

Feedback on Craig’s earlier work

Feedback on Craig’s earlier groundwork and customer service.

"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
— Verified CustomerMyBuilder · SO · Cobble edge and gravel strip
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
— Verified CustomerCheckatrade · BH20 · Garage base

Frequently asked questions

Can I book testing without buying a new screw foundation?

Yes. Testing is a standalone service and can concern an existing foundation, a trial installation or suitable screws fitted by another installer. The booking is based on the evidence required and whether the intended positions can be tested safely. You can contact us simply to discuss that testing work, without adding a new installation to the enquiry.

What information helps when another contractor installed the screws?

Any record identifying the screws and their positions is useful, along with installation information or a test request you have received. It helps us understand the foundation and the question being asked of it. If you do not have those records, explain what is known; we can discuss what needs clarifying before a suitable test scope is agreed.

What does a pull-out test measure?

It records the screw’s response when upward force is applied through the agreed arrangement. That evidence is used to examine uplift resistance at the tested point. The required loading and acceptance criteria need to be appropriate to the project.

What happens in a direct compression test?

Downward force is applied to the selected screw under the agreed test method, and the response is measured. This provides direct evidence of behaviour under that loading. It is different from a compression figure obtained through calculation from other evidence.

What does lateral testing show?

It shows how the tested screw and arrangement respond to force applied sideways in the chosen direction. That can help assess horizontal resistance and movement for the project’s requirements. The direction, connection and setup matter to the result, which is why they form part of the agreed test scope.

Can a compression assessment be calculated instead of directly tested?

A calculated assessment may be appropriate where a justified method applies to the product, evidence and conditions being considered. Its basis must be stated clearly. It should not be presented as though a downward physical test took place. If direct compression evidence is required, discuss that requirement when commissioning the work so the appropriate method is agreed.

Can installation torque monitoring be arranged?

Yes, as a separately agreed price-on-application service during installation. It records the resistance encountered while a screw is inserted. The timing and scope therefore need to be coordinated with that work. An insertion record is a different form of evidence from applying a specified physical pull, compression or lateral test afterwards.

What is specialist torsional testing?

It is a separately commissioned test applying twisting to investigate the relevant torsional behaviour. It is not simply a record of insertion resistance, and it is not a sideways load test. The proposed method, purpose and written output need agreeing. Specialist torsional testing is price on application and is not automatically included with another test.

Can a trial screw be tested before the full foundation is installed?

Yes, a suitable trial installation can be used to obtain evidence while the wider foundation is being planned. Agree the purpose and test requirements at that stage, including whether the commission covers supplying and fitting the trial screw or testing one already provided. Its removal or retention afterwards should also be clear in the scope.

Can screws be tested when a floor or building is already attached?

That depends on the accessible connections, existing loading and whether a safe test arrangement can be established. Describe the structure and the point you want tested, adding photographs only where they can be taken safely. Leave structural connections in place. We will discuss what can be assessed and tested before any work is booked.

Who specifies the test loads and acceptance criteria?

They follow the responsible project or design requirements for the evidence being sought. Those requirements need to be clear enough to agree the test method and interpret the result. You can make an initial enquiry without a completed brief; we can identify what needs confirming with the relevant designer or project contact before proceeding.

What written results or calculations will I receive?

We supply recorded test results and a written report. Any project-specific load calculations are agreed in the quotation and require an applicable method. Measured results and calculated evidence are identified separately, so you can see how the information was obtained. Send any particular reporting request when available so we can confirm its scope before booking.

Does a test report approve the whole building or foundation design?

No. The report provides evidence from the agreed work for the relevant assessment. The full design also involves the building’s loads, layout, connections and other foundation requirements, which remain with the responsible designer.

How do I start if I only know the site and reason for testing?

Send those details and the postcode, or call to explain what prompted the enquiry. We can establish whether you need a physical test, an installation monitoring discussion or another specialist scope, then clarify the information and access needed to quote it. Existing plans, records and photographs are welcome later; they are not a requirement for making first contact.

What does each additional ground screw test cost?

At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type. The first test of each type is priced separately, using the starting price for your location. The extra-test charges stay the same in every location.

What happens next

We will discuss the evidence needed, confirm whether suitable test arrangements can be made and agree the method, written output and price. The test is booked once that scope is clear.