Ground screw testing in Horsham
JustBases offers standalone ground screw testing in Horsham for homeowners, installers and project teams. We can test suitable trial foundations and existing screws, including another company’s installation, and provide recorded results, a written report and the agreed load calculations.
Tests for upward, downward and sideways forces
The force direction matters because the foundation may be asked to resist different actions. We establish which question needs answering, then agree a test that applies the relevant load and records the screw’s response.
Pull-out testing
An upward pull examines resistance to uplift or pull-out at the selected screw. The loading and resulting movement are recorded for the agreed assessment, helping the project team evaluate the foundation where upward force is part of the design.
Learn more: Pull-out testingCompression testing
A direct compression test pushes down on the screw and records its response under the applied loading. It provides downward test evidence; any separately agreed compression calculation based on pull results is identified as calculated, not presented as a downward measurement.
Learn more: Compression testingLateral testing
A lateral test applies force sideways to examine horizontal response. It can supply evidence where horizontal loading is relevant to the foundation design, with the direction, connection and test arrangement agreed for the project.
Learn more: Lateral testingGround screw testing prices in Horsham
The guide fees below distinguish the physical test methods. The quotation follows the actual programme: what needs testing, how many positions are involved, the setup and access, travel and any calculations required. A useful first description is what decision the results need to support.
Installation torque monitoring is a separate service recording turning resistance during driving. Specialist torsional testing applies a deliberate twisting action for a rotational assessment. Both are priced on application and neither is automatically included with the physical test fees. We confirm the selected services in writing before attendance.
Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.
- Pull test (tensile or uplift test)
- From £523
- Load test (compression test)
- From £1,045
- Lateral test (sideways load)
- From £512
- Installation torque monitoring
- Price on application
- Specialist torsional load test
- Price on application
Each additional test
Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.
- Pull test (tensile or uplift test)
- £160 extra
- Load test (compression test)
- £320 extra
- Lateral test (sideways load)
- £155 extra
No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.
Ask about testing your foundation
You may have a specific request from a designer, or simply need to understand whether testing could help with a new or existing foundation. Explain the situation and give the postcode. Craig can discuss the next information needed without asking you to assemble a technical pack first.
If a brief or screw record already exists, attach it or send it later. A call to 01202 039753, WhatsApp or the enquiry form all begin the same scope discussion; commissioning an installation is not required.
Request your free quote
Give us your contact details and a short description of the testing you need. You can ask before the technical requirements are complete.
Your enquiry
Ground screw testing in Horsham
Agreeing and carrying out the test
Before a visit is booked, the project team and tester need a clear purpose and a workable test arrangement. The responsible designer or assessor establishes the loads and acceptance criteria against which the results will be considered.
Identify the decision the test must support
Discuss the proposed structure or current foundation and the evidence being requested. Settle the test method, selected positions, loading requirements and calculations within the written scope, obtaining the relevant technical input where needed.
Set up and apply the agreed loading
Confirm that the screws and surrounding work area are suitable for the test and that the load can be applied safely. Carry out the agreed loading sequence and record the response, with any departure or stopping condition noted.
Review the recorded findings
Provide the written results and agreed calculations so the responsible person can use them in the project assessment. Where the findings leave a question unresolved, the next decision can be discussed using the actual measurements.
Testing before construction or on existing screws
If you are asking whether existing screws can serve a proposed building, explain the new building rather than only the structure that stood there before. The assessment needs the intended loads and supporting arrangement. The original product and installation records are useful where available; testing is a separately bookable part of that assessment.
For screws already connected to a building, preparation is led by a safe test plan. We need a way to apply the required force without putting the supported structure at risk. Leave fixings intact while that is assessed, and have any necessary opening-up, unloading or temporary support arranged by competent people.
A trial is useful while the foundation can still be developed in response to the findings. Tell us which design decisions remain open so the tester and assessor can agree the evidence needed at that stage. The quote confirms the trial installation and testing responsibilities, including the agreed treatment of the tested screw afterwards.
Using the results in your project
Use the written findings to settle the foundation decision that prompted the test. The assessor can compare the measured loading response with the required performance and explain what it means for the next work. If the result does not meet the requirement, agree the revised design or further investigation before that work relies on the foundation.
Keep the report with the building and foundation information so it can be reviewed in context. Its evidence concerns the tested supports and arrangements; it is not a certificate for the whole building or automatic Building Control approval. Any additional professional assessment or approval has to be commissioned through the appropriate route.
Booking a Horsham testing visit
Tell us the stage your project has reached and when the test information is needed. For a new foundation, there may be an opportunity to test before the building covers the supports. For an existing structure, the owner and the person responsible for any enabling work need to agree a safe, ready test area.
Where a contractor is coordinating the project, identify who can confirm the site is ready and who will answer technical questions about the required assessment. We can settle the visit details alongside the programme instead of leaving unresolved access or loading decisions until attendance.
You can book only the testing you need. If the project also requires a new foundation, Horsham ground screw installation explains that separate service. The Horsham overview covers the other base choices, and the West Sussex service area lists our other towns.
Testing enquiries in and around Horsham
Send the site postcode for testing in Horsham or the nearby places listed below. We can discuss the required evidence and practical visit arrangements for an address in a village as well as in the town.
RH12 and RH13 cover many local enquiries. Five Oaks is in RH14, while the named eastern villages extend into RH11 and RH17. The written quote confirms travel and the test scope for the full site address.
- Horsham neighbourhoods: the town centre, Denne, Forest, Trafalgar, Horsham Park, Kingslea, Millpond, Highwood, Blackbridge, Chesworth, Oakhill, Tower Hill and New Town.
- North Horsham and nearby: Holbrook, Old Holbrook, North Heath, Littlehaven, Roffey and Mowbray.
- Broadbridge Heath and the western villages: Wickhurst Green, Slinfold, Five Oaks, Itchingfield, Barns Green, Bashurst Hill, Two Mile Ash and Christ’s Hospital.
- Warnham and its surrounding communities: Kingsfold, Winterfold, Northlands, Durfold, the Station Road area, Goosegreen and Rowhook.
- Rudgwick and adjoining places: Bucks Green, Cox Green, Tisman’s Common and The Haven.
- Southwater and nearby villages: Shipley, Coolham, Brooks Green, Dragon’s Green, Cowfold, West Grinstead, Littleworth, Dial Post and Partridge Green.
- Nuthurst and Lower Beeding areas: Mannings Heath, Monks Gate, Nuthurst, Sedgwick, Copsale, Maplehurst, Lower Beeding, Crabtree and Plummers Plain.
- Towards Crawley and the eastern villages: Rusper, Lambs Green, Colgate, Faygate, Kilnwood Vale, Handcross, Pease Pottage, Slaugham and Warninglid.
Feedback on Craig’s earlier work
Feedback on Craig’s earlier groundwork and customer service.
"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
Ground screw testing questions
The right starting point is the question you want the test to answer. These answers explain how that becomes an agreed visit and useful written evidence.
Can I use JustBases only for testing another installer’s work?
Yes. Testing is a standalone service and does not depend on purchasing screws, a frame or a building from us. Describe the foundation and the reason evidence is needed. We review the proposed work and any available product information to establish which tests can be arranged.
What if I have been told to get a test but do not know which one?
Tell us who requested it and what they need to decide. An uplift question, a downward load requirement and a horizontal force require different evidence. We can clarify the intended assessment with the relevant person so the programme is properly defined before a visit, rather than asking you to choose a technical label unaided.
Will a downward test also establish uplift resistance?
It measures downward response under its particular loading and setup. Uplift is a different action and calls for the appropriate upward evidence if required by the design. Share all the forces the assessor needs to consider so we can quote the necessary programme rather than assume one direction answers the others.
When would lateral testing be useful?
It is useful when the project needs information on how a screw responds to a sideways force. That requirement can arise from the way the structure transfers horizontal loads to its supports. The assessor specifies the relevant direction and criteria, and the test setup is agreed around that requirement.
Does a trial need the complete building on site?
A trial concerns a selected screw installation rather than requiring the completed building. The proposed structure still matters because its foundation requirements define the evidence to obtain. The designer and tester settle the product, loading and useful test location before the trial is arranged.
Who decides where to test on a larger foundation?
The positions should be chosen as part of the assessment, with the responsible designer or assessor considering the structure, support requirements and information needed. The tester then checks whether the proposed arrangements are practical. Convenient access is useful, but the selected points must also provide evidence relevant to the project.
Can you test when the screw heads are already beneath a building?
We can assess the possibilities, but the applied load and working arrangement must be safe for both the test and the structure. Send photographs taken without disturbing anything and explain what the screws support. Any required opening-up, unloading or temporary support must be agreed with the competent people responsible before the visit.
Can the same programme test every type of screw?
A test has to suit the screw being loaded, its connections and the assessment. Product identification helps establish how the load can be introduced and which assumptions are available for interpretation. Tell us what is known; we confirm the scope once enough information is available for the test to be practical and useful.
Can installation torque be recorded while new screws are fitted?
That service can be agreed for the installation and is priced on application. It records resistance to turning during driving, which is different from applying a test load to an installed screw. The designer must establish any justified use of those records alongside the other evidence required for the foundation.
Is specialist torsional testing the same as sideways loading?
No. Torsional testing applies a twisting action to examine rotational response; a lateral test applies a horizontal force. Torsional work has its own agreed setup and is priced on application. If your project calls for rotation testing, identify that requirement explicitly so it is not confused with a lateral test or installation monitoring.
Can the report contain a calculated compression value?
An agreed calculation may use pull-test results where an applicable method and the necessary assumptions support it. The report must show that the figure is derived and explain its basis. If the recipient requires measured downward behaviour, ask for direct compression testing; a calculated value and a physical downward result are different evidence.
Does a successful test mean the complete building is approved?
It means the measured result can be considered against the agreed test criteria. The person responsible for the design must decide how that evidence supports the project and whether other work is needed. The report does not by itself approve the building or automatically satisfy an authority’s separate requirements.
What can change the price from the starting test fee?
The required methods, number of test positions, preparation and setup, access, travel and calculation work can change the scope. Additional visits may also be needed if the programme is split into stages. We establish these points in the quotation so the booked service reflects the assessment you need. At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type; the first test of each type is priced separately.
Can I arrange testing for a site in a village near Horsham?
Yes, send the exact postcode and describe the project stage and testing purpose. Include any date by which the findings are needed so the proposed visit can be discussed with the wider programme. The quote confirms the address, work and travel arrangements, with any required technical or site preparation settled before attendance.
Tell us what you need to find out
Use the testing enquiry form, call 01202 039753 or message Craig on WhatsApp with the purpose and postcode. You can attach existing information if convenient or discuss it with us first.
We will clarify the testing requirement, confirm whether the proposed arrangement is practical and provide a quotation before the visit is agreed.