Ground screw testing in Hungerford
JustBases offers ground screw testing in Hungerford as a standalone service, including suitable screws fitted by other installers. We discuss pull-out and compression testing, with lateral testing by arrangement, for trial positions or existing foundations. Tell us what the result needs to establish and we will help you agree the next step.
Ground screw tests we offer
A test can give the project team measured information before committing to a full foundation or deciding how to use existing screws. We establish the question first, then agree the loading method and positions that will provide the required evidence.
An upwards pull, a downward push and a sideways force are different investigations. Testing the relevant direction matters more than obtaining a report with the general label of load test. If an engineer or building supplier has asked for evidence, send their request if available; you can also start by explaining the situation in your own words.
Pull-out testing
An applied upward force investigates resistance to uplift. We agree the test loading and measurements so the recorded response relates to the selected screw and the purpose of the test.
Learn more: Pull-out testingCompression testing
A direct downward load examines how the screw responds when pushed into the ground. This provides compression evidence at the tested position, rather than treating an uplift result as though the screw had been loaded downwards.
Learn more: Compression testingLateral testing
By arrangement, a sideways load can be applied to investigate lateral response. Its direction, connection and loading requirements need to be established for the project, with enough room for a safe test setup.
Learn more: Lateral testingGround screw testing prices in Hungerford
The guide gives separate starting fees for the direct-load test methods. For a written price, we establish the number of positions and visits, required loads and measurements, available working room and reporting scope. Tell us whether tests are needed before other work can proceed, so the programme can be considered with the practical arrangements.
Installation torque monitoring and specialist torsional testing are each price on application. The first records turning resistance as a screw is installed; the second applies an agreed twisting load as a separate test. Say which information has been requested so a service is not booked under an ambiguous torque-test description.
Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.
- Pull test (tensile or uplift test)
- From £511
- Load test (compression test)
- From £1,021
- Lateral test (sideways load)
- From £500
- Installation torque monitoring
- Price on application
- Specialist torsional load test
- Price on application
Each additional test
Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.
- Pull test (tensile or uplift test)
- £160 extra
- Load test (compression test)
- £320 extra
- Lateral test (sideways load)
- £155 extra
No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.
Ask about a ground screw test
Start with the postcode and the reason for testing. Mention whether the screws are exposed or already connected to a frame. Any screw details, drawings or adviser instructions are welcome if available, but they are not needed to make first contact. Call 01202 039753 or message Craig on WhatsApp if explaining it by phone is easier.
Request your free quote
Describe the testing you need, even if you do not have a test specification yet.
Your enquiry
Ground screw testing in Hungerford
How ground screw testing works
We agree the test and the record needed before arranging the visit. This connects the practical work on site with the decision the owner, supplier or designer needs to make afterwards.
Purpose and test requirements
We discuss the loading direction, selected screw positions and the information the report must provide. Required test loads, sequence and acceptance criteria are agreed with the responsible designer where applicable.
Safe access and test setup
We establish how the equipment reaches the screws, how the test connection will be made and how the opposing force can be provided safely. An attached structure, restricted working space or another contractor's activity may affect those arrangements.
Measurements and report
The agreed load is applied and the relevant response measured and recorded. The written reporting scope identifies the results and any agreed calculations to be provided. The project team then uses that evidence against the specified requirements for the foundation.
Testing existing screws and trial installations
For an existing foundation, useful starting information includes the screw product if known, its positions, installation records and what is attached to the heads. We can begin with whatever you have. The test must be able to connect safely and apply the specified force without relying on an unsuitable part of the building.
If a fixed frame covers the heads, tell us and send an ordinary photo if accessible. Do not remove brackets, loosen connections or take flooring apart to make an enquiry. Any necessary access work and the responsibility for it must be agreed before the testing appointment.
A trial installation can provide information before a complete support layout is fitted. Agree the purpose and selected locations with the designer or supplier so the test is relevant to the proposed foundation. One tested position does not automatically stand for every location across a larger site.
What your test report tells you
The report records the agreed test method, loading and measured response for the identified screw positions. Confirm any required photographs, presentation of results or project-specific calculations when commissioning the work, especially if a designer or another organisation will use the report.
Results need to be interpreted against the requirements for the building and foundation. The responsible designer decides whether the tested response meets those criteria and what it means for the wider scheme. A test report is evidence for that decision, not automatic approval of all screws, connections and the structure above.
Keep a distinction between direct measurements and calculations. If another party proposes deriving a value from a different test or installation record, the method and its applicability need to be agreed. A torque log, an uplift test and a direct compression test should not be presented as the same measurement.
Arranging testing in Hungerford
Give us the work address and the point where the equipment can enter. This is especially useful for an outbuilding or rural plot whose access is separate from the house's postal entrance. Tell us who will provide entry and whether another contractor needs to be present, so the visit can be coordinated rather than arriving before the site is ready.
Include the full postcode and any simple directions needed to find the site entrance and test area. We confirm the journey and setup for the address before booking.
If you also need a new foundation, ground screw installation in Hungerford is a separate service to discuss. For the other base choices see Hungerford base installation, or find nearby services through the Berkshire guide.
Areas we cover around Hungerford
Enquiries are welcome from Hungerford town centre, Charnham Street, Eddington, Sanham Green, Hungerford Newtown, Leverton and Denford. East and south-east of the town, surrounding places include Kintbury, Avington, Inkpen, Combe, West Woodhay, Hamstead Marshall and Enborne.
To the north, we also serve Great Shefford, East Shefford, Shefford Woodlands, East Garston, Eastbury, Lambourn, Upper Lambourn, Lambourn Woodlands and Woodlands St Mary. Other nearby villages include Chilton Foliat, Froxfield, Ramsbury, Aldbourne, Baydon, Little Bedwyn and Great Bedwyn. To the south, we cover Shalbourne, Ham, Ham Spray, Buttermere, Oxenwood, Tidcombe and Fosbury. Explain whether upward, downward or sideways response needs checking, and identify the screw positions concerned. That gives the person specifying the test a clear basis for agreeing the loading programme.
Standalone testing is available in Hungerford and nearby RG17, RG20 and SN8 locations. Send the full site postcode and explain what is connected to the screw heads. We can agree access to the selected positions and identify who needs the written results, including any reporting deadline to discuss before the visit.
Feedback on Craig’s earlier work
Feedback on Craig’s earlier groundwork and customer service.
"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
Frequently asked questions
Answers about commissioning a useful test, preparing the site and understanding the results.
Will you test screws that JustBases did not install?
We can consider suitable screws supplied or installed by another company. The available connection, condition, access and purpose of testing need assessment before we confirm the work. Tell us what you know about the installation; missing paperwork does not stop an initial conversation, although further information may be needed to agree a test.
Can testing be booked without buying any new screws?
Yes. It is a standalone service. You can request evidence about an existing foundation or ask about a trial installation for a proposed project. We price the testing scope itself rather than requiring you to purchase a complete foundation installation from JustBases.
What is a pull-out test intended to establish?
It investigates the screw's response to an upward force, relevant where uplift resistance needs to be examined. The selected loading and movement measurements are agreed for the particular purpose. A pull-out result concerns the tested position and arrangement; its interpretation for the proposed structure belongs with the responsible designer.
Why might a designer request a compression test?
A direct compression test applies force downwards and measures the screw's response under that loading. It is useful where downward-load evidence is required. It should be specified as such rather than assuming an upward test or a turning-resistance record gives the same directly measured information.
Can you investigate sideways loading?
Lateral testing is available by arrangement. We need to establish the direction and required loading, the connection to the screw and enough safe working room for the setup. Send the request or describe what the foundation needs to resist so the appropriate scope can be discussed.
Can trial screws be tested before the rest are installed?
Yes, a trial can be discussed as part of establishing the foundation approach. Its positions and purpose should be selected to answer the project's questions, with any required designer input. Testing first does not by itself determine the whole layout; the results need to feed back into the foundation decision.
The heads are hidden beneath a timber frame. What should I do?
Tell us how the frame is connected and show any safely visible area. Leave structural fixings and flooring in place. We assess whether a suitable connection and working space can be arranged, then agree any necessary preparation and who will carry it out before a test visit is booked.
Who chooses the test loads and a pass or fail threshold?
Those criteria must come from the requirements for the project and the person responsible for its design, rather than a universal figure applied to every screw. We agree the required test procedure and measurements with that brief. If no brief exists yet, we can explain what needs settling before testing.
What should I expect to receive after the test?
The agreed reporting package records the method, tested positions, loading and relevant measured response. Explain before booking if your adviser needs particular data, photographs or project-specific calculations. The written quotation confirms what will be supplied so the report is useful to the people making the foundation decision.
Does a successful test certify the entire building?
No. It provides evidence about the screw or positions tested under the agreed conditions. The wider structure includes other foundations, the frame, connections and building loads. The responsible designer interprets the results in that context; a test report should not be used as blanket certification of elements it has not assessed.
Is installation torque monitoring a cheaper version of a load test?
It is a different measurement, not the same test at a different price. Monitoring records turning resistance as installation takes place. A physical load test applies an agreed force afterwards or as part of a trial. Which evidence is appropriate depends on the project requirements, and there is no universal torque-to-capacity conversion.
What if the request says torsion testing?
A specialist torsional test examines response to an applied twisting load. That is distinct from logging torque during installation and from pulling, pushing or loading sideways. Share the wording of the request so we can clarify the intended test, equipment arrangement and report. Torsional testing is priced on application.
Do the testing guide fees cover every visit?
They are starting guidance for the stated methods, not a fixed price for an unspecified number of tests. The selected positions, loading, access, preparation, visit arrangements and reporting affect the quotation. Tell us if a designer or frame installer needs to attend so coordination can be included when arranging the work. At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type; the first test of each type is priced separately.
Can you arrange testing outside Hungerford town?
Enquiries are welcome from the surrounding villages and districts named in the coverage section. Provide the full postcode and actual site entrance, plus any access constraints you know about. We confirm the visit for that address and test arrangement. If the results are needed before another contractor can proceed, mention that timing when enquiring.
What happens next
Explain what needs testing and where. We discuss the required evidence, agree the scope and written price, then arrange the visit and reporting. Send your testing enquiry, call 01202 039753 or message Craig on WhatsApp. You do not need to order an installation to speak to us.