Ground screw testing in Romsey
JustBases offers standalone ground screw testing in Romsey, including assessment of existing screws installed by another company. We provide pull-out and compression testing, with lateral testing by arrangement. Whether you are planning a foundation or checking one already fitted, start with the location and what you need to establish.
Ground screw tests we offer
Testing supplies measured information about how a screw responds under the loading agreed for the project. It can help a designer review a proposed foundation, investigate a trial position or assess suitable screws already installed. You can commission testing separately from a new installation.
We establish which force needs to be investigated, the test positions and the information required afterwards. If a designer or supplier has requested a particular test, share their instructions when available. An initial enquiry can also begin with a simple explanation of the question you need answered.
Pull-out testing
An upward test load measures the response relevant to uplift resistance. The agreed force and movement observations provide evidence for the selected screw and connection under those test conditions.
Learn more: Pull-out testingCompression testing
A direct downward load measures response in compression. This investigates how the screw behaves when pushed down, with the loading sequence and readings specified for the purpose of the test.
Learn more: Compression testingLateral testing
A sideways test is available by arrangement. We agree the loading direction, connection and measurement requirements, together with the space and safe setup needed to carry it out.
Learn more: Lateral testingGround screw testing prices in Romsey
The guide shows starting fees for the direct-load methods. Your written testing price follows the scope: the number of positions, required loading and measurements, visit arrangements, equipment access and reporting all need consideration. Tell us if the test is a condition for another contractor's next stage.
Installation torque monitoring and specialist torsional testing are separate services, both price on application. Monitoring records resistance to turning during installation. A torsional test applies a specified twisting load to investigate response. The requested method and information are agreed before the work is priced.
Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.
- Pull test (tensile or uplift test)
- From £489
- Load test (compression test)
- From £978
- Lateral test (sideways load)
- From £479
- Installation torque monitoring
- Price on application
- Specialist torsional load test
- Price on application
Each additional test
Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.
- Pull test (tensile or uplift test)
- £160 extra
- Load test (compression test)
- £320 extra
- Lateral test (sideways load)
- £155 extra
No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.
Ask about a ground screw test
Give us the work postcode and describe the reason for testing. Mention whether the screws are trials, exposed supports or connected to a frame. Send any existing brief, screw information or photos if convenient; you can enquire without those documents. Call 01202 039753 or message Craig on WhatsApp to talk it through.
Request your free quote
Tell us why testing is needed and where the screws are. We can discuss the requirements with you.
Your enquiry
Ground screw testing in Romsey
How ground screw testing works
We agree the technical purpose and practical arrangements together so the visit produces the information needed by the project team. The reporting requirements and interpretation responsibilities are established before testing proceeds.
Defining the test
The scope identifies the loading direction, screw positions, test sequence and measurements. Required loads and acceptance criteria are agreed with the responsible designer where applicable. We also establish who will use the report and any specific information they require.
Preparing the test position
We assess the connection to the screw and the safe means of applying the force, including the opposing force needed by the setup. Equipment access, working room and any attached frame are considered before confirming the visit.
Recording the results
The specified loading is applied and the relevant response measured. The agreed written report records the test and results, with any commissioned calculations or additional reporting details included in the scope. The project team can then assess that evidence against its requirements.
Testing existing screws and trial installations
For an existing installation, tell us what is attached and what information is available about the screw product and installation. Ordinary photographs of safely visible parts can help. We use that starting information to discuss a suitable test connection and the preparation that may be needed.
Where a floor or frame covers the heads, leave the structural connections intact while enquiring. We need to agree how access can be provided, who will carry out any preparation and how the test can be performed safely. That discussion should happen before an appointment dependent on exposed heads is booked.
A trial installation can be useful early in the foundation programme. Selected positions and test requirements should reflect the information the designer needs for the proposed scheme. Agreeing the trial's purpose helps its findings feed into the decision about the remaining foundation work.
What your test report tells you
The report describes the agreed test at its identified positions, including the loading and relevant measured response. If your engineer, supplier or approving organisation needs particular figures, photographs or calculations, discuss that requirement before commissioning the visit so the reporting scope can be confirmed.
The responsible designer uses the results to judge performance against the project's criteria. Other foundation points, frame members, connections and building loads also form part of the wider design. A test result therefore supports the design decision for its stated scope rather than certifying every part of the completed structure.
Installation monitoring and different physical tests should be identified clearly in the project records. A torque record reports installation resistance; pull-out, direct compression and lateral tests each measure response in their specified direction. Any calculated interpretation should state its agreed basis alongside the actual measurements.
Arranging testing in Romsey
Send the full postcode and the site entrance or access point for the work. Include any simple directions to the test positions and tell us who will provide entry. If the visit needs to be coordinated with the owner, frame supplier or designer, mention their involvement when discussing dates.
The surrounding villages listed below are welcome to enquire. We confirm the journey, access and equipment setup for the actual address, with the agreed reporting and any deadline considered as part of arranging the work.
For a new foundation, see ground screw installation in Romsey. You can also explore the other Romsey base services or find a nearby town in our Hampshire guide.
Areas we cover around Romsey
Enquire from Romsey town centre and the Abbey area, Cupernham, Tadburn, Woodley, Halterworth, Whitenap, Abbotswood, Ganger, Highwood, Crampmoor and Fishlake Meadows. Nearby places include Ampfield, Braishfield, Awbridge, Michelmersh, Timsbury, Mottisfont, Dunbridge and Lockerley.
We also welcome enquiries from East Dean, Sherfield English, Shootash, Embley, Woodington, East Wellow, West Wellow, Plaitford, Lee, Ashfield, North Baddesley, Chilworth, Nursling and Rownhams. Other surrounding villages include King's Somborne, Houghton, East Tytherley, West Tytherley and Frenchmoor.
SO51 covers Romsey and surrounding places, with nearby SO52 and SO16 addresses also useful when locating an enquiry. Give us the full postcode, including for a village or district not listed, so we can confirm the actual site and practical arrangements.
Feedback on Craig’s earlier work
Feedback on Craig’s earlier groundwork and customer service.
"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
Frequently asked questions
Help with choosing the test, arranging the visit and using the reported results.
Can I commission testing independently of an installation?
Yes. The testing service is available on its own, whether the aim is to investigate a trial position or assess suitable existing screws. We discuss the information needed and the practical test arrangements before quoting. There is no need to purchase a complete new foundation to make a testing enquiry.
Can another installer's screws be tested?
They can be considered, subject to assessment of the product, connection and site arrangements. Share the details you have, including what is already attached. We establish whether the specified force can be applied safely and what preparation or further information is needed before confirming the work.
Which test should I ask for?
Start with what the project needs to establish. Pull-out investigates upward loading, compression investigates downward loading and lateral testing examines sideways response. If a designer or supplier has requested a method, send their instructions. We can help clarify the request before the scope and visit are agreed.
Can a test be carried out before the full foundation is installed?
Yes, a trial can be discussed as part of the foundation programme. Its selected positions and loading should provide information relevant to the proposed design. The designer uses the results in deciding the next steps, so the purpose and reporting need to be established when planning the trial.
What if the screw heads are covered by a frame?
Tell us about the frame and send any safely accessible photos. Keep structural fixings in place while we discuss the test. The connection and working space need to be suitable, and any required access preparation must be agreed with the responsible parties before the visit.
Who decides the required load and acceptance criteria?
They are established from the project's design requirements, with the responsible designer specifying or agreeing the criteria where applicable. We confirm the loading sequence and measurements needed to carry out that test. If you have no brief yet, an initial conversation can identify what needs to be settled.
What working space does a test need?
It depends on the method, connection and how the load will be applied safely. The equipment needs access to the position and a suitable arrangement to provide the opposing force. Show the available space and any adjacent structure so those requirements can be assessed before booking.
What should I tell you about the report requirements?
Explain who will use the results and pass on their requested data or format if available. The quotation can then confirm the test record, measurements and any additional calculations or photographs included. Agreeing that scope early helps the report answer the project's actual question.
Will one successful test approve all the foundation screws?
A report concerns the positions and loading actually investigated. The designer considers how those results relate to the rest of the foundation and its required performance. The number and selection of test points should be agreed for the project so the evidence is appropriate to the decision being made.
How is a physical test different from an installation torque log?
A physical test applies a specified force and measures response. A torque log records turning resistance while the screw is driven. They provide different evidence, so the project brief should identify which is required. Installation monitoring is a separate price-on-application service and needs arranging before the information is collected.
Can you discuss a separate torsional test?
Yes. A specialist twisting-load test can be discussed using the screw details, requested loads and access information. It is distinct from both installation monitoring and the direct pull-out, compression or lateral tests. The scope and price are agreed on application for the particular requirement.
How do I arrange a test around the building supplier's schedule?
Tell us which stage depends on the results and any date already proposed. We need to agree access, site preparation, the test brief and reporting before confirming arrangements. Include the full postcode and relevant contacts so the visit can be coordinated with the people responsible for the site and next work.
What does each additional ground screw test cost?
At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type. The first test of each type is priced separately, using the starting price for your location. The extra-test charges stay the same in every location.
What happens next
Tell us what needs establishing and where the testing will take place. We agree the requirements and written price before arranging the test and report. Send a testing enquiry, call 01202 039753 or message Craig on WhatsApp.