Ground screw testing in Wareham
Request ground screw testing in Wareham for a proposed foundation, trial supports or suitable screws already in place. JustBases accepts testing-only enquiries, including another installer's work, with the methods, safe preparation and written findings agreed before the visit.
Ground screw tests we offer
Testing provides recorded evidence of how selected supports respond to agreed forces. You may need it while choosing a foundation arrangement or as part of a review of existing screws. We discuss what the results will be used for so the programme can be developed with the responsible designer.
Different loading directions examine different requirements. The selected method, screw information and test connection are considered together when arranging the work.
Pull-out testing
This method loads the support upwards to examine its uplift response. The applied force and movement are recorded for the selected screw, giving the project team evidence for the agreed pull-out requirement.
Learn more: Pull-out testingCompression testing
Direct downward loading measures the screw's response in compression. We also discuss project-specific compression calculations using pull-test evidence where an applicable method is agreed; the findings identify whether the value was measured downwards or calculated.
Learn more: Compression testingLateral testing
A horizontal load examines sideways response at an identified support. Its direction and application are planned around the requirement being investigated, with the relevant movement recorded during the test.
Learn more: Lateral testingGround screw testing prices in Wareham
Start with the method guides below, then request a quotation for the planned tests and reporting. The number of positions, loading arrangements, preparation, site access and travel all contribute to the actual scope. We also agree the written report and any project-specific calculations required.
Installation torque monitoring records turning resistance during installation. A specialist torsional test examines response to an applied twisting load. Both are price on application, arranged as distinct services when requested. Neither is automatically included with a pull, compression or lateral testing enquiry.
Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.
- Pull test (tensile or uplift test)
- From £492
- Load test (compression test)
- From £984
- Lateral test (sideways load)
- From £482
- Installation torque monitoring
- Price on application
- Specialist torsional load test
- Price on application
Each additional test
Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.
- Pull test (tensile or uplift test)
- £160 extra
- Load test (compression test)
- £320 extra
- Lateral test (sideways load)
- £155 extra
No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.
Ask about a ground screw test
You can start with the location and a plain explanation of what needs checking. Drawings, screw records or an engineer's brief are useful when available, not compulsory for first contact. Use the form, call 01202 039753 or message Craig on WhatsApp to discuss a testing quotation.
Request your free quote
Tell us the postcode and why testing is needed. Any existing technical information can be added when you have it.
Your enquiry
Ground screw testing in Wareham
How ground screw testing works
We turn the initial enquiry into a defined testing programme, with the work area and reporting arranged before attendance.
Agree the loading and test locations
The designer identifies the required load directions, loads and acceptance criteria. We discuss the screw product and available installation details, then agree the points, test method and information to provide. Any required calculations are included in that written scope.
Prepare a safe testing arrangement
Access to each support and the surrounding working area are reviewed for the proposed loading. We consider how the screw head and connections can be used safely. Clearance, temporary support or other enabling work is coordinated with the responsible site team where needed.
Record and explain the findings
The selected supports are tested under the agreed arrangements and their response is recorded. We supply the written results and commissioned calculations, identifying the test points and method. The project team can then use those findings in its foundation assessment.
Testing existing screws and trial installations
Where another company is involved in the foundation, clarify who is arranging the testing and who will act on the results. We can quote our testing separately and discuss the proposed work with the relevant project contact. This helps settle which tasks belong to the test visit and which remain with your installer or designer. For new supports from JustBases, see ground screw installation in Wareham.
A proposed trial needs an agreed review point: the results should reach the designer in time to inform the foundation work that follows. The trial specification, position and loading are set for that purpose. Include supplying and fitting the trial screw in the discussion, and confirm whether it will be removed or considered for use in the final foundation.
With screws already in service, we need to establish how testing can be carried out while the building remains safely supported. Tell us what is fitted above the screws and what you can see without disturbing it. Keep fixings and structural members in place. Any work to expose a connection, unload it or provide temporary support must have agreed responsibilities and a safe method, including reinstatement, before we attend. Existing screw records are useful if available; suitability is assessed for the proposed test.
What your test report tells you
Use the written report to discuss the foundation decision with your designer. It supplies evidence from the commissioned tests, with project-specific load calculations in the agreed scope. The designer considers whether that evidence meets the required criteria and what it means for the building, its connections and the complete foundation. Any approval or certification needed for the structure remains a separate decision; the test report supports that review.
Keep the report with the foundation documents so its findings remain attached to the relevant supports. A result can be followed back to the identified screw, loading method and recorded movement, with the available product and setup information providing context. Read the measurements alongside any calculations: a direct compression test records downward loading, whereas compression derived from pull evidence uses an agreed method applicable to the foundation and site. Its calculation basis and assumptions are explained so the reader can tell how that value was obtained.
Arranging testing in Wareham
A short explanation of the testing request and your Wareham-area postcode will start the discussion. We can work through the arrangements with you, including the report needed and when the evidence will be used. If the request came from an engineer or another contractor, forwarding it can help us clarify the work with them.
Before booking, make sure everyone involved knows what they are providing for the visit. We agree access to the selected screws, the available working area and any preparation by others. Give us a contact who can arrange entry and the full site address, with directions to the entrance we should use. Permissions for shared access and any work on a loaded structure need to be settled with the responsible people. These are booking arrangements we discuss together, not a technical pack you need before enquiring.
For other foundation work, visit the Wareham overview or local concrete service. For nearby towns, see our Dorset service areas.
Areas we cover around Wareham
We welcome enquiries from Wareham town, Bestwall, Northport, Carey and Northmoor, together with Sandford, Holton Heath, Organford, Lytchett Minster, Upton, Lytchett Matravers, East Morden, West Morden, Bloxworth and Bere Regis.
Nearby villages and smaller places include Stoborough, Stoborough Green, Ridge, Arne, Worgret, East Holme, West Holme, Holmebridge, Binnegar, East Stoke, Stokeford, Rushton, Highwood, Hethfelton, Woolbridge, Wool, East Burton and Bovington.
Ask about Furzebrook, Creech, East Creech, Norden, Corfe Castle, Church Knowle, Cocknowle, Steeple, Kimmeridge, Kingston, Harmans Cross, Langton Matravers, Worth Matravers, Studland and Swanage, or Coombe Keynes, East Lulworth, West Lulworth, Winfrith Newburgh, East Knighton and Moreton.
BH20 locates many Wareham and surrounding enquiries, with adjoining BH16, Purbeck BH19 and western DT2 addresses also welcome. Send the full postcode and directions to the actual entrance so we can confirm the service, access and travel for your property. We are happy to discuss an unlisted nearby address.
Feedback on Craig’s earlier work
Feedback on Craig’s earlier groundwork and customer service.
"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
Frequently asked questions
Answers about the tests, preparation and evidence available for your project.
Do I have to buy screw installation to request testing?
No. Testing is available as a standalone service, including suitable screws fitted by another company. Describe the existing foundation or proposed trial and the evidence you need. We assess the product information, connections and access before agreeing the work that can be carried out.
Can a programme examine more than one loading direction?
It can, where the design calls for the relevant evidence and suitable arrangements can be agreed. Pull-out, compression and lateral methods examine upward, downward and sideways response respectively. The programme identifies which directions are required at which points and how each result will be reported.
Can testing help before the full foundation is installed?
Yes. A trial can provide measured information for the designer to consider when developing the foundation. Discuss the proposed screws and construction timetable early, allowing time to agree the loading programme, test positions and how the findings will be used before further installation proceeds.
How are test positions selected?
The choice should follow the investigation or design question and the foundation proposal. Your designer determines the coverage of evidence needed, and we coordinate practical access and test arrangements for those positions. A plan identifying the supports helps everyone relate the tests and results to the project.
What if the technical testing request is not complete yet?
Start by explaining the project, postcode and reason for seeking evidence. If someone has requested a report, share their message when convenient. We discuss what must be clarified, including the method and loading requirements, before turning the enquiry into an agreed testing scope.
Who specifies the test load and assessment criteria?
Ask the person responsible for the foundation design to confirm the loading instruction and the response they need to assess. If you have only been told to obtain a test, we can discuss that request with you before those instructions are complete. The agreed criteria must be in place for the test to provide the evidence the designer requires.
Can screws supporting an occupied building be tested?
Tell us that the building is occupied when you enquire, so the proposed work can take account of its continued use and support. Suitability depends on being able to apply the required test safely at the selected connection. We discuss this with the responsible team, including any unloading or temporary works. Keep the existing structure intact while those arrangements are assessed.
What preparation might the site need?
A clear route and sufficient working room around the agreed positions are important. The required clearance depends on the test setup and loading direction. We discuss obstacles, head access, site permissions and preparation responsibilities in advance, so the work area can be safely ready for attendance.
What is the purpose of an installation torque record?
Request it before the screws are driven if the project needs a record of turning resistance during installation. That is when the monitoring takes place. It provides installation evidence, while a later pull, compression or lateral test examines response to an applied load. Monitoring has its own price-on-application scope and is not automatically included with installation or testing.
What does a torsional load test investigate?
Ask for specialist torsional testing when the requirement is to assess the screw under a twisting force. The specified rotational loading needs its own agreed test arrangement. It is different from a sideways lateral load and from monitoring turning resistance while driving the screw. We quote torsional testing on application, as a separately commissioned service.
How will I know whether compression was measured or calculated?
The report identifies the method used. Direct compression testing records response under a downward applied load. A compression calculation based on pull results is separately labelled and uses an agreed applicable method, with its basis explained. Confirm the form of evidence required by your designer before the test is booked.
Are calculations and a written report available?
Yes. The service supplies recorded findings and a written test report, with project-specific load calculations within the agreed commission. Tell us about any required document format, recipient or signature so the quotation can identify the appropriate scope and any specialist input before attendance.
Does testing approve the complete structure?
The designer remains responsible for deciding how the test findings apply to the complete structure. Our testing and report supply evidence for that decision, within the scope you commission. If approval is needed from building control or another body, agree with your designer what that submission must contain; a testing appointment does not itself provide that approval.
What happens between the first call and attendance?
We establish the intended evidence, review available screw and site information and agree a test programme with the required reporting. The written quotation covers that work. We then coordinate access, preparation, the site contact and timing, including any deadline for the results.
What does each additional ground screw test cost?
At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type. The first test of each type is priced separately, using the starting price for your location. The extra-test charges stay the same in every location.
What happens next
Enquire about Wareham testing, call 01202 039753 or message Craig on WhatsApp. We discuss the evidence required, agree the test programme and give a written quotation. Once the site preparation and access are confirmed, we arrange attendance and supply the agreed findings.