Detail of an installed ground screw

Ground screw testing in Alresford

JustBases offers separately booked ground screw testing in Alresford and nearby villages. We can discuss pull-out, compression and lateral tests for suitable trial or existing screws, including installations by other contractors, with the loading and purpose agreed before the visit.

Choose the measurement your project needs

A test can help the person responsible for a foundation make a defined decision. You might need evidence before choosing a support system, a measurement against a specified requirement or information about an existing screw. Tell us the decision first; we can then discuss a test that produces relevant evidence.

The force direction matters. Uplift, downward load and sideways load are separate questions, and the response measured in one direction does not establish performance in all three.

Pull-out testing

An upward load is applied to investigate resistance to uplift. The test records the response under the agreed loading sequence and limits, giving the assessor evidence for the selected screw and test conditions.

Learn more: Pull-out testing

Lateral load testing

A sideways load investigates lateral response. The point and direction of loading must suit the question being asked, including the relevant head or connection arrangement. It is not included automatically with a pull-out or compression test.

Learn more: Lateral load testing

Ground screw testing guide prices

The guide prices below are starting points for the named physical tests. The quotation confirms the method, test points, practical setup and records to be provided. Tell us if the request covers several positions or forms part of a larger foundation assessment.

Two other services have separate prices on application: installation torque monitoring, which records turning resistance as a screw is inserted, and specialist torsional load testing, which applies an agreed twisting load. Neither is an automatic part of a physical load test or a standard installation.

Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.

Installation torque monitoring
Price on application
Specialist torsional load test
Price on application

Each additional test

Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.

Pull test (tensile or uplift test)
£160 extra
Load test (compression test)
£320 extra
Lateral test (sideways load)
£155 extra

No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.

Tell us why you need a test

Start with the full postcode and what you need to find out. Say whether the proposed test is for a trial screw or a foundation already installed. If a designer, supplier or project manager has requested the work, their question or test request will help us clarify the next step.

Documents can follow. You can use the form, call 01202 039753 or WhatsApp Craig before you have assembled drawings, installation records or a full specification.

Request your free quote

Give us your contact details and a short description of the testing you need. You can ask before the technical requirements are complete.

Your enquiry

Ground screw testing in Alresford

Please provide either an email address or a phone number.

Add site photos, video or a drawing (optional)

Upload up to 5 photos or a short video of your site to help us provide an accurate quote.

0/5 files. JPG, PNG, WebP, PDF, MP4, MOV accepted — up to 100MB each.

Free, no-obligation quote. Your details are used to respond to this enquiry; see our privacy policy.

Agree, carry out and record the test

We confirm the loading plan and the arrangements needed to carry it out safely. The agreed scope establishes both what will be measured and the question the resulting record is intended to address.

Identify the question and proposed screw

We discuss the requested decision and the screw or position available for testing. Relevant product information and the present condition help establish whether the proposed work is suitable.

Set the test method and limits

The force direction, loading sequence, measurement requirements and stopping limits are agreed before testing. Acceptance criteria follow the responsible design or assessment requirement and are confirmed before the visit.

Apply the agreed load and measure response

The setup applies the specified load and records the corresponding response. The work remains within the agreed procedure, with any departure or limit recorded so the results can be understood correctly.

Issue the record for review

The record identifies the tested work and what happened under the applied load. The responsible assessor can compare it with the stated requirement and decide what the foundation proposal needs next.

Testing before or after installation

For a planned foundation, decide what a trial needs to represent before the test point is installed. The selected screw and trial arrangement should be relevant to the proposed work. A useful trial allows the findings to inform the decision that follows, such as confirming a proposed support or reviewing the specification.

For an existing foundation, tell us what is supported now and why further evidence is wanted. Suitable screws may be considered even if another contractor installed them. Access to the required point and a safe way to apply the load must be established before the test is accepted.

Leave any connected structure supported while the test arrangements are assessed. If an opening, unloading or temporary support is needed, that work must be planned by the competent people responsible before testing. Photographs can start the discussion without you removing part of the building.

Using the results for the next decision

The test record identifies the selected screw or point and records the applied loading and observed response. We supply the recorded results in a written report, with the project-specific load calculations agreed in the quotation. The person using the findings can see what was measured and compare it with the requirement agreed for the test.

The person assessing the foundation decides what follows from those findings. Testing may support acceptance of the proposed work or indicate that further assessment is needed. The report is evidence from the agreed test, not a certificate for the complete building; design acceptance and any statutory approval remain separate responsibilities.

Booking a test at your property

If you are arranging the visit for someone else, identify the person who can authorise the testing and site preparation. We agree the work and written quotation with that person before the visit is booked.

For a new foundation, our Alresford installation service explains the screw and frame options. For other base methods, see garden building bases in Alresford, or check where we work in Hampshire.

Testing in Alresford and the adjoining villages

Enquiries are welcome from New and Old Alresford and the surrounding places listed below. Give us the full postcode and purpose of the test so we can confirm the property and the proposed visit.

SO24 is the main Alresford enquiry district, with neighbouring addresses around Itchen Abbas in SO21, Four Marks and Medstead in GU34, and Preston Candover in RG25 also considered. We agree the testing arrangements for the actual site.

New Alresford

The town centre and Broad Street, The Dean, Jacklyns Lane, Sun Lane and Sun Hill, The Avenue, Grange Road, Beech Road, New Farm Road and Tichborne Down.

Old Alresford and smaller settlements

Old Alresford, Fobdown, Pinglestone, Godsfield, Nettlebeds, Armsworth, Upper Lanham, Lower Lanham and Upton.

Bishops Sutton, Bighton and Gundleton

Enquiries from these adjoining villages and the properties between them are welcome.

Tichborne and the Cheriton-side villages

Tichborne, Cheriton, Beauworth, Kilmeston, Bramdean and Hinton Ampner.

Itchen Stoke and the Itchen Valley

Itchen Stoke, Ovington and Abbotstone; Itchen Abbas, Avington, Easton and Martyr Worthy.

Northington and the Candovers

Northington, Northington Down, Swarraton and Totford, together with Brown Candover, Chilton Candover and Preston Candover.

Ropley, Wield and adjoining villages

Ropley, Ropley Dean, Monkwood, Upper Wield, Lower Wield, Four Marks, Medstead, West Tisted and East Tisted.

Feedback on Craig’s earlier work

Feedback on Craig’s earlier groundwork and customer service.

"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
— Verified CustomerMyBuilder · SO · Cobble edge and gravel strip
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
— Verified CustomerCheckatrade · BH20 · Garage base

Ground screw testing questions

You can enquire as a homeowner, installer or professional arranging evidence for a foundation. We will separate the initial request from the technical details needed to confirm the test.

What should I ask for if I am unsure which test I need?

Describe the reason you need evidence and who will use it. For example, a foundation designer may have asked for a measurement before accepting a support arrangement. We can help clarify which test is being requested, but the loading and acceptance requirement should be confirmed with the person responsible for that decision before the test goes ahead.

Can I book testing without buying a screw foundation from JustBases?

Yes. Testing is available as a separate service for suitable trial and existing screws, including another contractor's installation. Tell us the location, purpose and what is in place. We will confirm whether the proposed test can be carried out safely and define the scope independently of any installation purchase.

Are pull-out, compression and lateral tests interchangeable?

No. Pull-out testing loads upward, compression testing loads downward and lateral testing applies a sideways force. Each investigates the response in that direction under the agreed conditions. If the design needs evidence for more than one direction, the required methods must be identified and quoted separately so the work produces the right information.

Who sets the load to be applied?

The test plan follows the foundation's design or assessment requirement. The responsible person establishes the required loads, acceptance criteria and limits, with a suitable procedure agreed before the visit. Those details allow the practical setup and measurements to be planned for the required test.

When is it useful to test a trial screw?

A trial can be useful while a foundation proposal can still be reviewed in response to the findings. Agree the proposed product, location and arrangement with the person specifying the foundation so the trial addresses their question. Its result is evidence for the tested conditions; the assessor decides how it can be used for the proposed installation.

Can an existing screw be tested while a building is attached?

It may be possible, but suitability must be assessed for the particular setup. Tell us what the screw supports and show the connection if you can do so safely. The planned test must protect the structure and people around it, with any required unloading or temporary support arranged before loading. Do not dismantle it just to make an initial enquiry.

What if I cannot see the screw head?

Say what covers it and send an accessible view of the area if available. We can discuss how the point might be assessed and what access would be needed for the proposed test. Any opening-up work must be planned with the person responsible for the structure before testing, with suitable support maintained.

Can a pull-out result also provide compression information?

Only where an agreed method is applicable to the product, site and purpose, and the calculation's basis and assumptions are documented. That is calculated evidence, not a direct compression measurement. A direct compression test applies downward load and measures the response. Confirm which evidence the designer or recipient needs before the scope is fixed.

What does installation torque monitoring tell me?

It records resistance to turning while the screw is being installed. It is separately agreed and priced on application. This insertion record differs from measurements under a later upward, downward or sideways load; any use in a capacity assessment needs an applicable technical basis for the system, method and project.

How does a specialist torsional test differ?

It applies a separately defined twisting load to assess rotational response, rather than recording the resistance encountered during insertion. The loading arrangement, measurements and purpose need their own agreement. It is priced on application and is not automatically supplied with installation monitoring or with pull-out, compression or lateral testing.

What does movement during a test mean?

It must be read alongside the applied load, test method and agreed criteria. A number without that context cannot establish whether the specified requirement has been met. The record provides the observed response under the test conditions, and the responsible assessor uses it to reach the appropriate foundation decision.

Who should receive the test record?

Give it to the person responsible for the foundation assessment, together with the test request and the relevant design information. If another organisation has asked for evidence, identify its requirements before booking. We agree the written deliverables in the quotation so the result can be passed on for the decision it was commissioned to support.

Will the screw still be usable after it is tested?

That depends on the test objective, the loads reached and the response of the screw and its surroundings. Agree the intended future use before testing, including whether the point is a trial or part of the finished foundation. Its suitability afterwards must be assessed from the actual test and relevant design requirements.

Can more than one test direction be included in a booking?

Yes, an agreed programme can cover the different physical tests the project needs. Each direction requires the appropriate method and setup, and the quoted scope should show which tests and points are included. Tell us the full requirement when enquiring so we can discuss a practical visit covering the requested work.

What does each additional ground screw test cost?

At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type. The first test of each type is priced separately, using the starting price for your location. The extra-test charges stay the same in every location.

Ask about a ground screw test

Tell us what you want the test result to help decide and the property's full postcode. Add any request you have received from the designer or other assessor when it is available. We will explain the proposed scope before you commit to the visit.

Use the form or call 01202 039753. If your project needs both installation and testing, mention both so the work can be arranged in a useful sequence.