Detail of an installed ground screw

Ground screw testing in Brockenhurst

JustBases offers ground screw testing as a standalone service in Brockenhurst. Whether you are arranging a trial or checking suitable installed screws, including another installer's work, we can discuss the test and written evidence needed for your project.

Physical load tests for ground screws

The direction of the load matters to the evidence you receive. Pull, compression and lateral tests examine upward, downward and sideways behaviour respectively. Tell us which action your designer or project team needs to investigate so the visit can be planned around it.

If a compression assessment is requested, confirm whether it requires direct downward loading or an applicable calculation from pull-test data. A calculated assessment uses an agreed method for the particular product and project, with its assumptions identified. It is reported separately from a physical compression measurement.

Pull testing

The screw is subjected to agreed upward loading while its response is recorded. This gives the reviewer evidence for the specified uplift or tension check.

Learn more: Pull testing

Lateral testing

Sideways loading is applied in the agreed direction and at the specified application point. The observations can then be assessed against the relevant horizontal-load criteria.

Learn more: Lateral testing

Ground screw testing prices

Use the testing guides to help plan the budget, then ask us to quote the required visit. The testing schedule, site readiness, access and agreed written results establish the scope, including any calculations requested by the project.

Installation torque monitoring and specialist torsional testing are separately available, each price on application. Monitoring records the resistance to turning as the screw is inserted; a torsional test applies an agreed twisting load. Neither is automatically included with the physical load tests. Specify the service you need, because an insertion record and an applied-load result provide different information.

Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.

Installation torque monitoring
Price on application
Specialist torsional load test
Price on application

Each additional test

Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.

Pull test (tensile or uplift test)
£160 extra
Load test (compression test)
£320 extra
Lateral test (sideways load)
£155 extra

No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.

Tell us why you need a test

A project description and postcode will start the conversation. If someone has requested the testing, you can send their instruction when available. We can discuss the service before you have gathered drawings, screw records or a complete technical brief.

Request your free quote

Explain what you need checked and where the site is. Any existing instruction or photographs can be added when you have them.

Your enquiry

Ground screw testing in Brockenhurst

Please provide either an email address or a phone number.

Add site photos, video or a drawing (optional)

Upload up to 5 photos or a short video of your site to help us provide an accurate quote.

0/5 files. JPG, PNG, WebP, PDF, MP4, MOV accepted — up to 100MB each.

Free, no-obligation quote. Your details are used to respond to this enquiry; see our privacy policy.

From a testing request to recorded evidence

We establish the work with the people who need to use the findings. The agreed procedure and criteria give the test a clear purpose, while the preparation plan makes the site ready for it. Those details are resolved before attendance rather than being prerequisites to your first enquiry.

Identify the required evidence

Tell us what the result will be used for and who will review it. The instruction should identify the action being checked and the relevant requirements for the foundation. Available screw and installation details help us discuss whether the proposed test is suitable.

Agree the procedure and safe setup

The specified loads, loading stages, selected positions and acceptance criteria are brought into a testing schedule. We assess the practical arrangements for applying the load and obtaining readings, including suitable reaction space and any preparation by other contractors.

Test and record the response

The scheduled work applies loading and records the resulting response at the identified positions. Conditions that affect the procedure or the meaning of a reading are kept with the record. If the planned test cannot be completed, the outstanding requirement can be discussed with the project team.

Provide the agreed results

We issue the written test information and any calculations included in the commission. The responsible designer or reviewer can then assess the findings against the project requirement and confirm what should happen next.

Testing trial screws and existing foundations

Tell us what is physically on site now, as well as what you hope to establish. Access to an unloaded screw is different from access to a support carrying a finished building. We use that starting condition to discuss a suitable procedure and identify who needs to prepare the site.

An exposed or trial installation

For a proposed foundation, trial testing can supply evidence while the design is still being developed. The designer should identify the investigation needed, including the relevant screw and position. Agree the supply and fitting of trial screws and what happens to them after testing, especially if their later use in the building is intended.

On an installed but still exposed foundation, coordinate the testing date with the next contractor. Keeping the agreed test points accessible allows the scheduled work to take place before a floor or other construction restricts them. Suitable screws fitted by another installer can be considered, using the information available about them.

Supports beneath a building

A standing structure needs a safe method for any testing that affects its supports. Show us which heads and connections can be reached, and leave structural members and fixings undisturbed while the method is assessed. Opening up, unloading or temporary support must be planned with the responsible designer and competent contractors.

For third-party property or installation work, make sure the necessary permission and relevant records can be obtained. We will confirm the proposed test and any enabling work before the appointment. You can begin that discussion with photographs and a description without dismantling the building.

Reading the result against the agreed check

Read the report with the testing requirement beside it. The useful question is whether the recorded test addresses the agreed loading and movement criteria, and what any stated qualification means for the decision. Identifiable test positions, observations and the procedure followed give the reviewer the context needed to assess the outcome.

Where a value has been calculated, its method and assumptions need to be clear, particularly for compression derived from pull data. Measured downward response is a different record. The responsible designer decides how the findings apply to the complete support system and building; a test report does not automatically provide that whole-structure approval. Tell us before booking if a specific report format is needed.

Arrange the visit around your project

Include time for the results to be considered when planning work that depends on testing. The appointment, written report and design review are separate stages in that programme. Knowing when you need the decision helps us discuss a realistic sequence before other contractors are committed.

At the site, agree who will meet us or provide entry, which supports must remain available and where the work area can be kept clear. If another contractor is preparing access or completing support work, confirm their stage is finished before the test visit. Full address and entrance directions can be supplied as the appointment is arranged.

For a new foundation as well as a test, the Brockenhurst installation page explains the separate screw and frame service. We can discuss how the testing fits the project without requiring you to buy installation to commission a suitable test.

Testing around Brockenhurst

We welcome testing enquiries in Brockenhurst village and the residential areas around Waters Green, North Weirs, South Weirs, Culverley Green and Balmer Lawn. The surrounding area includes Rhinefield and Rhinefield Road, Setley, Dilton, Roydon and Hincheslea.

Nearby communities from which you can enquire include Sway, Shirley Holms, Battramsley, Boldre, Pilley, Pilley Bailey, Bull Hill and East Boldre; Tiptoe, Hordle, Everton, Wootton and Holmsley; and New Milton, Ashley, Bashley and Barton on Sea. We also welcome enquiries from the neighbouring Lyndhurst, Lymington and Burley areas. Give us the actual property address so we can discuss the work and travel for that site.

SO42 includes Brockenhurst addresses, with SO41 examples around Sway and Boldre, SO43 around Lyndhurst, BH24 around Burley and BH25 around New Milton. These are useful location references rather than whole-district commitments. Send the full postcode and any entrance directions needed when arranging a visit.

Feedback on Craig’s earlier work

Feedback on Craig’s earlier groundwork and customer service.

"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
— Verified CustomerMyBuilder · SO · Cobble edge and gravel strip
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
— Verified CustomerCheckatrade · BH20 · Garage base

Questions about testing

Who can ask you to carry out a ground screw test?

We welcome enquiries from property owners, building suppliers, contractors and designers. Explain the project and why evidence is needed, so we can establish the appropriate service with you. The person responsible for the design or project acceptance should define the requirement the results will be assessed against.

Can you test a foundation installed by a different company?

Yes, where the product, arrangement and access are suitable for the proposed work. Ask for any screw specification and installation records that are available, and arrange the owner's permission to test. We can discuss what is known and identify any further information needed without tying the enquiry to a new installation purchase.

What if I have been asked for a load test but not told which one?

Send the wording of the request and tell us who needs the result. We can explain the physical services, then clarify the required direction and procedure with the relevant project instruction. That avoids booking a test before the person using the evidence has established what it needs to demonstrate.

How are acceptable load and movement limits established?

They need to be defined for the project's design and agreed test procedure. The testing schedule should include the required loading and the criteria to be used by the reviewer. We carry out and document the agreed check, while the responsible designer or other specified reviewer assesses its relevance to the foundation.

What does physical compression testing involve?

It involves applying a downward load and observing the tested screw's movement under that loading. A suitable loading and reaction arrangement must be possible at the site. Let us know when a direct compression measurement is required so it can be identified in the quotation and preparation plan.

Can pull testing also be used in a compression assessment?

Only where an applicable calculation approach has been agreed for the product and project. In that case the pull readings are evidence for a calculation, not measurements from downward loading. The reviewer needs the calculation basis and assumptions to decide how to use the result; direct compression testing should be commissioned if that is the specified requirement.

What details are important for a lateral test?

The specified load direction and application point establish the sideways action being investigated. The procedure also needs its loading sequence and movement criteria. Providing the relevant instruction lets us discuss a setup that addresses that question and record an outcome the reviewer can relate to it.

Can I arrange trials before committing to the main foundation?

Yes. Discuss the proposed investigation with the designer while its result can still influence the specification. The trial needs a defined screw, position and loading requirement, with supply and installation included or allocated explicitly. Leave time for the evidence to be reviewed before ordering the following foundation work.

Does a floor above the screws prevent testing?

It changes the access and preparation that must be considered, but you can still ask us to assess the enquiry. Show the existing arrangement without disturbing it. A safe plan may require opening up, unloading or temporary support by competent people, agreed with the person responsible for the structure before testing can proceed.

What if I have few records for the installed screws?

You can enquire with the information you hold. The next task is to identify the installed product well enough to agree a suitable test, so ask the original installer or supplier for missing paperwork if possible. We will tell you which gaps affect the proposed work before confirming the booking.

Can the tested screw be kept in the finished foundation?

Agree that intention before the test is specified. The loading procedure and observed behaviour can affect continued use, so retention is a design decision rather than an assumption attached to the visit. Where replacement or removal may be needed, its responsibility should be included in the project arrangements.

Will the report certify my whole building?

The report provides the agreed test evidence, identifying the checks carried out and the results obtained. Your responsible designer or reviewer uses that information within the wider foundation assessment. Any required inspection, design approval or formal acceptance of the completed building needs its own clearly agreed responsibility.

Should I request installation monitoring or torsional testing?

That depends on what you need to establish. Monitoring records turning resistance during insertion; torsional testing deliberately applies a twisting action to examine the response. Both are price on application and separately arranged, not automatic parts of physical load testing. Share the request so the intended service can be identified.

Do I need an engineer's brief to start an enquiry?

No. Give us the location and describe the reason for testing in ordinary terms. We can explain the options and the further details needed for a quotation. Before attendance, the scope, criteria and safe arrangements must be agreed, but you can contact us while those requirements are still being developed.

What does each additional ground screw test cost?

At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type. The first test of each type is priced separately, using the starting price for your location. The extra-test charges stay the same in every location.

Discuss your testing requirements

Call 01202 039753, use WhatsApp or send an enquiry above. We can start with the purpose of the test and the postcode, then work towards an agreed testing scope and written price.