Ground screw testing in Chichester
JustBases offers standalone ground screw testing around Chichester, providing loading evidence for trial screws and suitable existing installations, including screws fitted by others. We agree the required pull-out, compression or lateral tests, carry out the defined programme and report the results for your project team.
Ground screw tests we offer
A defined test can help a designer assess a foundation proposal, check a trial installation or obtain evidence from existing screws. The programme identifies the direction and magnitude of load, how response will be measured and the criteria the responsible designer or specifier needs applied.
Installation torque monitoring measures turning resistance while the screw is installed. Specialist torsional testing examines response to an applied twisting load. They are different commissions, both price on application, and neither is interchangeable with the direct load tests below.
Pull-out testing
An upward force is applied to measure the tested screw's response to uplift. The agreed loading stages and movement observations provide evidence for that direction at the test position.
Learn more: Pull-out testingCompression testing
Direct compression testing loads the screw downwards and measures its response. A compression calculation derived from other evidence is a separate assessment, with its method and assumptions identified rather than described as a direct downward test.
Learn more: Compression testingLateral testing
A sideways load is applied in the specified direction to assess lateral response. We agree the head connection, loading arrangement, measurements and reporting required for the intended foundation detail.
Learn more: Lateral testingGround screw testing prices in Chichester
The testing guide below is a starting point for discussing the required evidence. We confirm the test method, number of positions, loading programme and reporting, together with the site access and safe connection arrangements, before providing the written price.
Tell us whether the screw is a trial, exposed foundation or part of a completed structure. Any trial installation, preparation, disconnection or reinstatement is identified where agreed. Installation torque monitoring and specialist torsional testing are quoted separately, both price on application.
Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.
- Pull test (tensile or uplift test)
- From £506
- Load test (compression test)
- From £1,012
- Lateral test (sideways load)
- From £496
- Installation torque monitoring
- Price on application
- Specialist torsional load test
- Price on application
Each additional test
Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.
- Pull test (tensile or uplift test)
- £160 extra
- Load test (compression test)
- £320 extra
- Lateral test (sideways load)
- £155 extra
No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.
Ask about a ground screw test
Explain why the test is needed, the postcode and the current project stage. You might be planning a new foundation, checking screws before a frame is fitted, or seeking evidence from an existing installation. Tell us who has requested the results if that is known.
An initial enquiry does not need a completed technical pack. Available drawings, screw records, photos and the designer's brief can follow. We help clarify the required programme before the work is agreed. Use the form, phone 01202 039753 or message Craig on WhatsApp.
Request your free quote
Give us your contact details and a short description of the testing you need. You can ask before the technical requirements are complete.
Your enquiry
Ground screw testing in Chichester
How ground screw testing works
The commission starts with the evidence needed and ends with a report of the agreed work. Test arrangements are established before the visit so the loads can be applied safely and the observations are useful to the person reviewing them.
Agree the test programme
We establish the purpose, screw positions, loading directions and required stages with the project contact. The responsible designer or specifier supplies or agrees the loading and acceptance requirements, including any hold periods and movement limits needed for the assessment.
Assess access and connections
We review the screw heads, frame connections, working space and proposed reaction arrangement. Existing structures may need an agreed safe sequence before loading can be applied. Preparation and reinstatement responsibilities are confirmed as part of the scope.
Apply loads and report results
The specified programme is carried out and the applied loads and observed response recorded. The report identifies the tested positions, method and relevant conditions, with calculations distinguished from measurements for review against the agreed requirements.
Testing existing screws and trial installations
A trial can provide evidence while the foundation is being designed, before the full installation and frame are committed. Agree what the trial needs to establish, the chosen position and screw specification, and how the results will inform the design. The test evidence relates to that agreed trial and its conditions.
Existing screws can also be considered, including another installer's work. Records of the product, installation and connections help us understand the arrangement. Where records are limited, we assess what can be established and whether the proposed test can be safely and usefully carried out.
An attached frame or building changes how a screw can be accessed and loaded. Share photos and drawings if available, then let us assess the connections and working space. Any release, temporary support or reinstatement must be planned with the responsible parties; leave structural connections intact for that assessment.
What your test report tells you
The report describes the commissioned test: the screw and position identified, loading direction and method, applied loads and measured response, together with relevant observations and limitations of the arrangement. Agree any particular identification, format or supporting records needed by the report recipient in advance.
A measured result and a calculation serve different purposes. If compression is assessed using a calculation from other evidence under an applicable agreed method, the report identifies the calculation, assumptions and evidence used. It is not recorded as though a direct downward loading test had taken place. Installation torque records are likewise identified as monitoring data.
The responsible designer or specifier reviews the findings against the project's acceptance requirements. The report provides evidence for the tested foundation elements and conditions; it does not certify the whole building, its frame, connections or compliance. Agreeing the intended use of the results before testing helps make the commission useful.
Arranging testing in Chichester
Once the test purpose is clear, we agree the site contact, attendance arrangements and report recipient. Tell us about access hours, the unloading route and any work planned around the test positions. Testing is easier to coordinate when the frame and building programme leave the agreed heads and working space accessible.
If a building is already in place, its connections and any temporary works are assessed before a date and method are confirmed. If the screws are still to be installed, discuss the trial or test stage with the installer so the proposed sequence supports the required evidence.
We also offer ground screw installation in Chichester. The Chichester overview covers the full base offer, while the West Sussex hub lists our service towns. A testing enquiry remains a standalone service.
Areas we cover around Chichester
Enquire about testing at a Chichester site or in the surrounding places below. Include the full postcode and the reason for testing so we can assess the attendance, connections and reporting scope for your written quote.
- Chichester city areas: city centre, Parklands, East Broyle, West Broyle/Minerva Heights, Summersdale, Graylingwell, Roussillon Park, Oaklands, Portfield, Whyke, Kingsham, Stockbridge, Westgate and St Pancras.
- Fishbourne, Bosham and Southbourne area: Fishbourne, Apuldram (Appledram), Bosham, Broadbridge, Chidham, Hambrook, Nutbourne, Southbourne, Prinsted, Hermitage, Lumley, Thornham, Westbourne, Aldsworth and Woodmancote.
- Funtington and Stoughton area: Funtington, East Ashling, West Ashling, West Stoke, Stoughton, Walderton, Racton and Lordington.
- Lavant and Dean villages: Lavant, Mid Lavant, East Lavant, West Lavant, Binderton, West Dean, Chilgrove, Singleton, Charlton and East Dean.
- Westhampnett and Boxgrove area: Westhampnett, Maudlin, Westerton, Boxgrove, Halnaker, Strettington, Crockerhill, Tangmere and Eartham.
- Oving and Mundham area: Shopwyke, Oving, Colworth, Drayton, Merston, Hunston, North Mundham, South Mundham and Runcton.
- Birdham and Wittering area: Donnington, Birdham, West Itchenor, West Wittering, East Wittering, Bracklesham, Earnley, Almodington, Batchmere and Somerley.
- Sidlesham area: Sidlesham, Sidlesham Church, Sidlesham Common, Highleigh, Ham and Sidlesham Quay, plus nearby Selsey enquiries.
- Aldingbourne and Pagham area: Aldingbourne, Norton, Westergate, Woodgate, Lidsey, Shripney, Eastergate, Barnham, Pagham, Nyetimber and Rose Green.
- Postcode enquiries: PO18, PO19 and PO20, with nearby addresses in PO10, PO21 and PO22. The complete postcode helps us confirm the arrangements for your site.
Feedback on Craig’s earlier work
Feedback on Craig’s earlier groundwork and customer service.
"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
Frequently asked questions
These answers explain test selection, existing-installation assessment and the evidence produced.
Can you test an installation completed by another contractor?
Yes, suitable installations by others can be assessed for a standalone testing commission. We review the available screw information, connections and site access alongside the evidence required. The test method and safe working arrangement must be agreed before the visit, especially where a frame or building is already attached.
How do I know which loading direction is needed?
The foundation design and evidence requirement determine the test. Pull-out applies upward load, compression applies downward load and lateral testing applies sideways load in an agreed direction. Explain who has requested the evidence and why; the responsible designer or specifier agrees the relevant directions and loading programme.
Can a trial be tested before the main installation?
Yes, a trial screw can be used to obtain evidence during foundation planning. Its product, position and programme should be chosen around the design question being investigated. We agree what is to be installed and tested, who supplies it and how the resulting report will be used before arranging the trial.
Can a screw be tested with a building still attached?
That depends on its connections, the available access and a safe way to apply the required load. An attached structure may need an agreed temporary-support or release sequence, coordinated with the responsible designer and contractor. Send information for assessment and leave structural connections in place until the safe method has been agreed.
What if I have no installation records or finished test brief?
Start by describing the installation and why evidence is needed. Available photographs, product details or drawings can help, and we assess what further information must be established. The loading programme and reporting requirements are then agreed with the appropriate project contact before testing; a complete pack is not required for the first enquiry.
Who sets the test loads and acceptance criteria?
The responsible designer or specifier supplies or agrees the project's requirements. These may include loading stages, duration and movement criteria as well as the test direction. We agree the programme against that brief so the results can be reviewed against those project requirements.
How many screws should be tested?
The number and positions follow the foundation's test plan and the question the evidence needs to answer. The designer or specifier considers the installation and relevant variation when defining that plan. We price and arrange the agreed positions; a result from one screw describes that tested element and its conditions.
What does installation torque monitoring record?
It records turning resistance as the screw is driven into the ground. It is an installation record, not a direct uplift, compression or lateral test. Any design use of that information requires an applicable agreed method; we do not apply a universal torque-to-capacity conversion. Monitoring is a separately agreed, price-on-application service.
How is specialist torsional testing different?
A specialist torsional test applies a twisting load to assess the screw's response under an agreed programme. Installation monitoring instead records resistance during driving. Torsional testing is separately scoped and price on application, with the required purpose, connections and reporting agreed for the project.
What should I expect in the written report?
The report identifies the commissioned method, tested screw positions, applied loading and measured response, together with relevant observations and conditions. Calculations are distinguished from measurements. Tell us before booking if the recipient needs a particular format, identification system or supporting information so that requirement can be included.
Is calculated compression the same as a compression test?
No. A direct compression test applies downward load and measures the response. A compression assessment calculated from other evidence uses an applicable agreed method and its assumptions. Where that assessment is commissioned, the report states the method and evidence used and does not present it as a direct downward test.
Does a test report approve the whole building?
No. It supplies evidence about the tested foundation elements and conditions under the agreed programme. The responsible designer or specifier uses that evidence within the wider assessment of the frame, connections, building and relevant requirements. Agree the report's intended use and recipient at the outset.
How should the site be prepared for testing?
Provide the agreed access and a clear working area around the test positions, and share known service information and site restrictions. The connection and reaction arrangement determines any further preparation. Any structural release, temporary support or reinstatement follows the safe method agreed with the responsible parties.
What happens between my enquiry and a booked test?
We clarify the evidence needed, review the available installation and access information, and agree a safe method and reporting scope. A written quotation follows those requirements, including any preparation or trial work. The visit is then coordinated with the site contact and the stage at which the agreed positions can be accessed.
What does each additional ground screw test cost?
At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type. The first test of each type is priced separately, using the starting price for your location. The extra-test charges stay the same in every location.
What happens next
Ask about your ground screw test, phone 01202 039753 or message Craig on WhatsApp. Explain the purpose and postcode, and we will work through the required test, safe site arrangement and report before agreeing the scope, written price and visit.