Detail of an installed ground screw

Ground screw testing in Frome

JustBases provides standalone ground screw testing in Frome, with pull-out, compression and lateral tests and an agreed written report. We can consider trial screws before a full installation or suitable existing supports, including those supplied or fitted by another company.

Ground screw tests available in Frome

Testing provides measured information about the response to loading at specified support positions. It can help a project team develop a foundation design, assess selected installed screws or obtain evidence before fitting the building. The useful starting point is the decision the results need to inform.

The agreed test programme identifies the loading direction and method, the screws involved and the record required. Tell us what has been requested or describe the project if those requirements are still being worked out. We can discuss the next steps without an accompanying installation order.

Pull-out testing

The test applies uplift to the selected screw and measures its response under the agreed sequence. It is useful when evidence is needed for upward forces acting through the foundation.

Learn more: Pull-out testing

Compression testing

Direct compression testing applies force downwards and records the response. A compression assessment derived through an applicable alternative method needs its basis and assumptions agreed and identified separately from that direct test.

Learn more: Compression testing

Lateral testing

A lateral test loads sideways in the specified direction. Connection height and the loading and measurement arrangement help define what has been examined, allowing the designer to review the response for that load case.

Learn more: Lateral testing

Ground screw testing prices

Compare the testing guides with the programme your project needs. The written price confirms the test methods and positions, loading sequence, access and setup, reporting and any agreed calculations. Working around an existing frame or arranging more than one attendance can affect that scope.

Installation torque monitoring records resistance to turning while a screw is installed. A specialist torsional test instead investigates a separately applied twisting load. Both torque services are price on application and require an agreed purpose and scope; monitoring is not an automatic part of installation or load testing.

Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.

Installation torque monitoring
Price on application
Specialist torsional load test
Price on application

Each additional test

Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.

Pull test (tensile or uplift test)
£160 extra
Load test (compression test)
£320 extra
Lateral test (sideways load)
£155 extra

No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.

Request a testing quotation

Give us the postcode and explain what the results are needed for. Mention whether the screws have yet to be installed, are exposed, or already carry a structure. If a designer or supplier has asked for a test, their request is helpful when available.

We will explain what must be agreed before testing, including the loads, criteria and safe access. You can start without drawings or installation records and send available information later. Complete the form, call 01202 039753 or message Craig on WhatsApp.

Request your free quote

Give us your contact details and a short description of the testing you need. You can ask before the technical requirements are complete.

Your enquiry

Ground screw testing in Frome

Please provide either an email address or a phone number.

Add site photos, video or a drawing (optional)

Upload up to 5 photos or a short video of your site to help us provide an accurate quote.

0/5 files. JPG, PNG, WebP, PDF, MP4, MOV accepted — up to 100MB each.

Free, no-obligation quote. Your details are used to respond to this enquiry; see our privacy policy.

From test requirements to a report

A defined programme makes the results useful to the people responsible for the project. We agree what will be tested and measured, how the load can be applied safely and which information the report will contain.

Define the loading programme

The responsible designer establishes the required loads and acceptance criteria. We coordinate the test method, positions, stages and any hold periods around those requirements, including agreed stopping conditions and the intended treatment of the tested screw.

Prepare safe access and connections

The screw head and surrounding working area are assessed for a suitable connection and reaction arrangement. Where a frame is attached, the project team must establish the safe support and loading plan before any agreed preparation takes place.

Carry out and document the tests

Loads are applied in the agreed sequence and the relevant movements or responses recorded. The written report identifies the test locations, method and findings, together with the details and limitations needed for their interpretation.

Testing before or after installation

A trial gives the designer evidence while the foundation arrangement is being developed. The proposed screw, ground and selected location need to relate to the question being investigated. Agree how the findings will inform the installation and whether the trial screw is to remain in the finished foundation.

For an existing foundation, drawings, product information and installation records help establish what is at each position. If those records are incomplete, share what you do have and identify the parts you can see. We can discuss the further identification or assessment needed to define a suitable test.

A completed floor or attached frame can limit access to the screw head and affect how loads would be transferred during testing. Photographs from accessible positions help us plan the review. Any opening up, temporary support or structural disconnection is agreed with the appropriate responsible parties as part of a safe working arrangement.

Using the results for your project

The report should let its reader identify which screws were examined, how the load was applied and what was recorded. Method, positions, load stages and relevant movement or response are set out with the agreed reporting detail. Any exceptions or setup limitations that affect the evidence remain part of that record.

Direct measurements and calculated assessments have different bases. A derived compression value is identified with the applicable method and assumptions, rather than presented as a measured downward load test. Any installation torque information also needs the appropriate interpretation for the screw system, ground and design requirements; there is no general torque-to-capacity formula for every situation.

The designer reviews the findings against the agreed criteria and determines the design implications or further action. A report on selected screws is evidence for that review, not certification of the entire building, its frame and connections or every untested support. The quotation identifies any project calculations included in our agreed service.

Arranging testing around Frome

Alongside the postcode, show how the proposed test positions can be reached and what surrounds them. Useful details include gate widths, steps, the unloading area and available working space near the screw heads. The reaction arrangement needs to suit the chosen loading direction as well as the route into the site.

Tell us about access permissions and the order of other work, such as fitting the floor or closing the underside of a frame. Identifying the designer, supplier or contractor who will review the test requirements helps coordinate the visit and report with the next project decision.

For additional supports, see ground screw installation in Frome. Our Frome overview explains the wider foundation offer and the Somerset service area gives the county context. Testing can be commissioned on its own.

Testing coverage around Frome

Ask us about a base or test in Frome and the surrounding places below. BA11 is the main local postcode district; nearby enquiries can also come from BA2, BA3, BA4, BA12 and BA13 addresses. Give us the full site postcode so the work and visit arrangements can be confirmed for that address.

  • Frome town areas: town centre, Keyford, Lower Keyford, Little Keyford, The Butts, Trinity, Gould's Ground, Welshmill, Innox Hill, Packsaddle, Fromefield, Stonebridge, Clink, Berkley Down, Wallbridge, Adderwell, Easthill, The Mount, Marston Gate, Critchill, Egford Hill and Low Water.
  • Selwood and the immediate surroundings: Oldford, Spring Gardens, Rodden, Rodden Down, Friggle Street, Elliots Green, Feltham, Blatchbridge, Tytherington, East Woodlands, West Woodlands, Egford and Hapsford.
  • Beckington and other surrounding villages: Berkley, Beckington, Standerwick, Rudge, Lullington, Rode, Tellisford, Woolverton, Norton St Philip, Farleigh Hungerford, Laverton, Hemington, Hardington, Foxcote, Faulkland and Buckland Dinham.
  • Mells, Whatley and neighbouring villages: Great Elm, Mells, Upper Vobster, Lower Vobster, Whatley, Chantry, Leigh on Mendip, Coleford, Kilmersdon, Babington, Nunney and Nunney Catch.
  • Trudoxhill and adjoining villages: Trudoxhill, Marston Bigot, Witham Friary, Upton Noble, Wanstrow and Cloford.
  • Wiltshire fringe enquiries: Chapmanslade, Huntenhull Green, Short Street, Thoulstone, Corsley, Corsley Heath, Whitbourne Springs, Longhedge, Lane End, Dertford, Sturford, Lyes Green and Horningsham.

Feedback on Craig’s earlier work

Feedback on Craig’s earlier groundwork and customer service.

"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
— Verified CustomerMyBuilder · SO · Cobble edge and gravel strip
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
— Verified CustomerCheckatrade · BH20 · Garage base

Frequently asked questions

These answers explain test preparation, loading and reporting. You can raise the enquiry before all the technical details have been settled.

Can I commission a test on another company's ground screws?

Yes, suitable screws supplied or installed by another company can be considered for our standalone testing service. Share the reason for the test and any details available about the installation. We agree the relevant programme and safe access independently of any order for new screw installation.

What if the request just says the screws need load testing?

Send the request as you have it and explain the project. We can help clarify whether the required evidence concerns uplift, downward compression, sideways loading or another specialist question. The method and criteria must be agreed before testing, but they do not need to be complete for an initial enquiry.

Can testing help while the foundation is still being designed?

A trial can provide information about a selected screw and position before the full foundation is installed. The designer needs to establish which evidence would help and how the trial relates to the planned design. That allows the results to inform the specification and subsequent work.

What is the difference between testing to a set load and investigating a limiting response?

A check to an agreed load and criteria has a different purpose from a test intended to investigate a limiting response. The programme needs to state its loading and stopping conditions, and what happens to the screw afterwards. The responsible designer agrees whether the screw can remain in use afterwards.

Who decides the test loads, positions and number of tests?

The responsible designer establishes the evidence and acceptance requirements for the foundation. These inform the positions and loading programme, coordinated with the practical test method. The written scope records the agreed tests, stages and reporting so the visit addresses those requirements.

Can a foundation be tested with the frame already attached?

That depends on access to the selected screw and the effect of the test on the connected structure. The loading and reaction arrangement must be suitable, with any temporary support or preparation agreed by the appropriate parties. Show the current arrangement so this can be assessed before work is booked.

Do missing screw records prevent me from enquiring?

No. Tell us what is known and send any available photographs or drawings. Further identification or assessment may be needed to establish a meaningful test, and that can be discussed. Initial contact is the place to explain the gaps, not a requirement to produce a complete installation record first.

Which site photographs help plan testing access?

A view of the screw heads and their surroundings, together with the route to them, is useful. Include nearby walls, frames, steps and narrow openings that can affect the working area. Use accessible viewpoints; any opening up or structural changes are considered through the agreed preparation plan.

Can a calculated compression figure be reported as a direct compression test?

They are different forms of evidence. Direct compression physically applies a downward load and records the response. A calculated figure derived through another applicable method needs its basis and assumptions stated and accepted for the project. The report identifies that distinction clearly.

How is installation torque monitoring used?

It records the resistance to turning as a screw is driven. The information may be useful when interpreted through an appropriate method for the system and ground, but it is not a direct loading test or a universal measure of every capacity. Monitoring must be specified and is price on application.

What would a specialist torsional test measure?

It examines the response to an agreed twisting load applied as a separate test. That differs from the turning resistance recorded during installation and from upward, downward or sideways testing. The specialist scope is discussed for its particular purpose and is price on application.

What results and calculations will I receive?

The agreed report records the test positions, method, loading and relevant measured response, together with setup details and limitations. Any calculations form part of the explicitly agreed scope. Tell us who will use the report and any information they require so it is planned into the programme.

Does a successful test give approval for the whole building?

The findings concern the identified screws under the agreed test conditions. The responsible designer reviews them against the project criteria alongside the rest of the foundation, frame and connection design. A test report does not itself certify the whole structure or provide automatic building-control approval.

Can tests be arranged in stages as the work progresses?

Discuss which positions will be accessible and when the findings are needed. A staged programme can be considered around the installation and subsequent construction, with safe arrangements for each visit. The quotation should identify the tests, attendances and reporting included so the sequence is clear.

What does each additional ground screw test cost?

At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type. The first test of each type is priced separately, using the starting price for your location. The extra-test charges stay the same in every location.

Talk to JustBases about testing