Detail of an installed ground screw

Ground screw testing in Marlborough

JustBases provides standalone ground screw testing in Marlborough, including suitable screws supplied or installed by others. We can test a trial installation or an existing foundation under the required upward, downward or sideways loading, and supply recorded results and a written report.

Ground screw tests we offer

Choose the test for the force the project needs to assess. We agree the required loading, positions and criteria with the responsible project team before carrying out the work; you can begin by explaining the building or foundation in ordinary terms.

Compression testing

A physical compression test pushes downwards and measures the resulting movement. We can also provide compression calculations from pull data where a justified method is applicable and agreed; a calculated value is identified separately from a direct downward test.

Learn more: Compression testing

Ground screw testing prices in Marlborough

The guides below help you budget for physical testing. A written quote confirms the test programme and practical setup, taking account of the required methods, number of positions, site access and visits.

Recorded results and a written report are supplied. Project-specific load calculations are agreed within the quotation, including the method and scope required for the project. Any additional professional design or signing service needs its own agreed scope.

Installation torque monitoring records resistance to turning during fitting: price on application. Specialist torsional testing applies a twisting action: price on application. These are different services, commissioned separately rather than included automatically in a physical test.

Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.

Installation torque monitoring
Price on application
Specialist torsional load test
Price on application

Each additional test

Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.

Pull test (tensile or uplift test)
£160 extra
Load test (compression test)
£320 extra
Lateral test (sideways load)
£155 extra

No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.

Ask about a ground screw test

Tell us the site postcode and what you need to find out. It helps to know whether this is a proposed foundation, a trial screw or an existing installation. Any request from a designer or screw information can be sent when available.

Use the form, call 01202 039753 or choose WhatsApp. You do not need to select a test load or compile a drawing pack before asking for a conversation.

Request your free quote

Give us your contact details and a short description of the testing you need. You can ask before the technical requirements are complete.

Your enquiry

Ground screw testing in Marlborough

Please provide either an email address or a phone number.

Add site photos, video or a drawing (optional)

Upload up to 5 photos or a short video of your site to help us provide an accurate quote.

0/5 files. JPG, PNG, WebP, PDF, MP4, MOV accepted — up to 100MB each.

Free, no-obligation quote. Your details are used to respond to this enquiry; see our privacy policy.

How ground screw testing works

The test is planned to answer an agreed project question. We establish a practical and safe way to obtain that evidence, carry out the loading and provide the findings in writing.

Define the evidence needed

We discuss why the result is required and agree the method and test scope with the project team. The responsible designer sets the relevant loading and acceptance requirements; the quotation identifies the work to be carried out.

Arrange and carry out the test

The selected screw and its surroundings are assessed for a suitable connection and safe test setup. We apply the agreed loading and record the response, including any relevant limitation or reason the planned loading cannot be completed.

Supply results and a written report

You receive the recorded findings and report, with project-specific load calculations as agreed. The evidence identifies how the result was obtained, so the project team can distinguish measured behaviour from an applicable calculated value.

Testing existing screws and trial installations

For an existing foundation, testing may be requested by the owner, building supplier or project professional. It can be a separate commission from the original installation. Let us know what is already attached to the screws, so the proposed test can take account of the foundation in its current condition. We assess whether the chosen screw can be connected to and loaded safely.

A trial installation lets the project team obtain evidence while a foundation proposal is still being developed. The screw and location to be tested are agreed for that purpose. We can discuss the testing alongside Marlborough installation if trial screws or a new foundation also need to be fitted.

Please send existing information as it is. You do not need to expose a buried head or disconnect a structural fixing to make an enquiry; any work needed to make testing possible must be assessed and arranged safely.

What your test report tells you

The written report explains the test carried out and the observed response to its loading. Recorded results are accompanied by the project-specific load calculations agreed in the quotation. The report is not automatic whole-building certification.

Arranging testing in Marlborough

The quotation confirms the agreed visit and work. Tell us about any constraints on reaching or working at the selected screws, and we will establish the arrangements for the actual test. The Marlborough service overview covers base installation as well as testing, and our Wiltshire service area gives the wider location information.

Areas we cover around Marlborough

We welcome enquiries from Marlborough, Manton and the surrounding places below. Send the site postcode so we can confirm arrangements and include the requested work and travel in your quotation.

Useful postcode examples include SN8 around Marlborough and many adjoining villages, SN4 around Broad Hinton and Winterbourne Bassett, and SN9 around Pewsey and Milton Lilbourne. Coverage is confirmed for the address, rather than every property within those districts. Wootton Rivers also has SN8 addresses.

Marlborough and Manton

Marlborough town centre and High Street, The Green, College Fields, St Margarets Mead, St Martins, Poulton Hill, Elcot Lane, Bath Road, London Road, Salisbury Road, Preshute Lane, West Manton and Manton.

Adjoining parish areas

Preshute, Manton House, Clatford, Mildenhall (Minal), Poulton and Stitchcombe; Savernake, Forest Hill, Cadley and Clench Common.

Ogbourne villages

Ogbourne St Andrew, Ogbourne Maizey, Rockley and Ogbourne St George.

Kennet villages and Avebury

Fyfield, Lockeridge, West Overton, East Kennett, Avebury, Avebury Trusloe, Beckhampton and West Kennett.

Broad Hinton and neighbouring villages

Broad Hinton, Winterbourne Bassett, Uffcott, Berwick Bassett and Winterbourne Monkton.

Ramsbury and Bedwyn villages

Axford, Ramsbury, Aldbourne, Baydon, Froxfield, Little Bedwyn, Chisbury, Great Bedwyn, Crofton and St Katharine’s.

Pewsey-side villages

Oare, Huish, Wilcot, Pewsey, Wootton Rivers, Milton Lilbourne, Easton Royal, Burbage, Durley, Stibb Green and Ram Alley.

Grafton villages

East Grafton, West Grafton, Wilton near Grafton, Marten and Wexcombe.

Feedback on Craig’s earlier work

Feedback on Craig’s earlier groundwork and customer service.

"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
— Verified CustomerMyBuilder · SO · Cobble edge and gravel strip
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
— Verified CustomerCheckatrade · BH20 · Garage base

Ground screw testing questions

These questions cover commissioning a test and understanding the evidence it provides.

Can a building owner book testing directly?

Yes. You can contact JustBases without first ordering an installation or asking the original installer to book for you. Explain why evidence is needed and give the site postcode. Before testing, we agree the requirements with the responsible project people, including the person setting the design or acceptance criteria.

Can you test screws fitted by a different installer?

We welcome those enquiries and assess whether the proposed screws can be tested safely and usefully. Any product details or installation records you already hold help that assessment. Start with what is known about the foundation and what it supports; missing paperwork can be discussed rather than treated as a barrier to the first call.

Which test addresses resistance to lifting?

Pull-out testing applies an upward force and records the screw’s response. It is the relevant physical direction when the agreed question concerns uplift. The loading and test position must match the project requirement; an upward result is not a direct measurement of downward or sideways behaviour.

What does a direct compression test measure?

It measures how the selected installed screw responds when downward load is applied. The loading and resulting movement form part of the evidence supplied. That is different from calculating compression capacity using another test result, which must use an applicable agreed method and be described as a calculation.

When would sideways loading need its own test?

If the foundation design requires evidence of horizontal response, a lateral test applies that force in the agreed direction. The project designer establishes what is needed for the structure. Upward pull and downward compression measurements do not directly measure that sideways response.

Can a trial help before the full foundation is installed?

Yes. An agreed trial can provide site evidence while the support proposal is being developed. The project team identifies what it needs to learn and the screw or positions relevant to that question.

Who agrees the load and acceptance requirements?

The responsible designer or project professional establishes the loading and response requirements for the foundation. We discuss how the test can be carried out and recorded to meet that brief. Those matters are settled before the loading is performed.

What if I only know that my project needs testing?

That is enough to start a conversation. Tell us what is being built or supported, the site postcode and who has asked for evidence, if anyone. We can explain the different test directions and discuss the next information needed to agree a suitable scope with the project team.

What happens if an installed head is covered by the frame?

Tell us what covers it and share a photo if one is readily available. The condition and connection need assessment before a loading arrangement can be confirmed. Please leave structural components in place for the enquiry; any necessary opening-up or temporary support must be planned by the appropriate responsible people.

Is installation torque monitoring a load test?

No. It records turning resistance as a screw is installed, rather than applying a separate upward, downward or sideways load to an installed screw. Its interpretation depends on the applicable screw and site information. Monitoring is a separately agreed price-on-application service, not a substitute automatically supplied with physical testing.

What is specialist torsional testing for?

It examines response to an applied twisting action where that is required by the project. This is distinct from monitoring the torque used while installing a screw and from loading it sideways. The test requirement and arrangement are agreed specifically, with a separate price-on-application quotation.

What paperwork do I receive?

We supply the recorded results and a written test report. The quotation also agrees the project-specific load calculations required and their method or scope. If the project needs an additional design service or a particular professional signing arrangement, that must be established separately rather than assumed to come with every test.

Can calculated compression evidence be used instead of a direct downward test?

That depends on the project’s evidence requirement and whether an appropriate calculation method applies to the screw and site. Where agreed, compression calculations may use pull-test data and relevant project information. They are labelled as derived evidence; a requirement for a direct physical compression test must be addressed as such.

Does the test report approve the entire building?

No. It records the agreed testing and provides evidence for the responsible designer or approval body to consider. Their decision concerns the complete foundation and building requirements, not just the response of the tested screw. Testing does not carry an automatic building approval or a warranty of the whole structure.

What does each additional ground screw test cost?

At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type. The first test of each type is priced separately, using the starting price for your location. The extra-test charges stay the same in every location.

What happens next

Send a testing enquiry with the site postcode and reason for the test. We will discuss the requirement, agree the work and written price, then arrange the testing.

For a conversation, call 01202 039753 or use WhatsApp. If you also need supports fitted, see ground screw installation in Marlborough.