Detail of an installed ground screw

Ground screw testing in Salisbury

JustBases provides ground screw pull, compression and lateral testing in Salisbury, including standalone enquiries for suitable trial screws and existing foundations installed by others. We agree the loading method and measurements around the evidence your project needs, then record the findings for your designer to assess.

Tests for uplift, downward load and sideways force

A load test shows how the tested screw responds when force is applied in a specified direction. Matching that direction and the loading sequence to the design question makes the result useful: a foundation may need evidence for more than one type of force.

The test plan identifies the screws, loads, measurements and acceptance criteria needed. Building loads pass through its frame and connections into the screws and then the ground; the designer considers that complete route when specifying and reviewing the foundation.

Pull testing

An upward load is applied to examine uplift resistance and the screw's movement. This can provide evidence for a design that must resist lifting forces, with the target and permitted movement set in the agreed test brief.

Learn more: Pull testing

Compression testing

A downward load test measures the response under compression. It helps assess the support needed beneath the building or frame; a direct compression test is specified when direct downward-load evidence is required.

Learn more: Compression testing

Lateral testing

A sideways load examines lateral resistance and displacement in the agreed direction. The test height and connection arrangement matter because they influence the response that the designer needs to interpret.

Learn more: Lateral testing

Ground screw testing prices in Salisbury

The guide below provides a starting point for the main load tests. We confirm a quotation against the required directions, number of test positions, loading sequence, access and reporting scope. Tell us if testing must take place within another contractor's programme so the visit can be planned appropriately.

Installation torque monitoring measures resistance to the turning of a screw while it is being installed. Specialist torsional testing separately applies a twisting load to examine rotational response. These are different services, both priced on application; neither is automatically included with a pull, compression or lateral test.

Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.

Installation torque monitoring
Price on application
Specialist torsional load test
Price on application

Each additional test

Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.

Pull test (tensile or uplift test)
£160 extra
Load test (compression test)
£320 extra
Lateral test (sideways load)
£155 extra

No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.

Start with the question your test needs to answer

Send the project purpose and postcode, even if the test requirements are still being developed. You can add photographs, screw details or an engineer's brief when available. For an initial discussion, call 01202 039753 or use the quote and WhatsApp options.

Request your free quote

Give us your contact details and a short description of the testing you need. You can ask before the technical requirements are complete.

Your enquiry

Ground screw testing in Salisbury

Please provide either an email address or a phone number.

Add site photos, video or a drawing (optional)

Upload up to 5 photos or a short video of your site to help us provide an accurate quote.

0/5 files. JPG, PNG, WebP, PDF, MP4, MOV accepted — up to 100MB each.

Free, no-obligation quote. Your details are used to respond to this enquiry; see our privacy policy.

How a testing visit is prepared and carried out

Agreeing the test before the visit helps everyone work towards a clear decision. We establish the practical arrangement and the evidence to be recorded alongside the designer's requirements.

Define the evidence

Identify whether the enquiry concerns a trial, a completed installation or a particular design check. The responsible designer supplies or agrees the test direction, loading requirements, locations and criteria needed for the assessment.

Check access and the test arrangement

We review access to the screw heads and the space needed to apply the load safely. Existing frames, underground services and neighbouring structures are considered before the test arrangement and any enabling work are confirmed.

Apply the agreed loads

The specified test sequence is followed, recording the applied loads and corresponding movement. Any relevant departure, restriction or observation is documented so the result can be understood in its actual test conditions.

Record and issue the findings

The written record identifies what was tested and how it responded. It is provided for the agreed recipient to review against the design criteria and decide whether further testing or a foundation change is needed.

Trial screws and existing installations

A trial screw can provide useful information before the final foundation arrangement is committed. Its location, screw specification and installation record should be chosen with the proposed design in mind. The designer decides how far the findings can be used for other positions and whether additional test locations are needed.

Testing can also be commissioned separately for a suitable existing installation, including screws fitted by another installer. Share the available product information, installation records and reason for the check. We establish what can be accessed and tested meaningfully before agreeing the work.

If a building or frame is already connected, keep it in its normal supported condition while the enquiry is assessed. Any unloading, temporary support or disconnection must be planned by the appropriate competent people. We agree the necessary enabling work and responsibilities before the testing visit.

A report your designer can use

Useful reporting connects the measured response to an identifiable screw and method. The agreed record includes the test location or reference, available screw details, the loading arrangement, applied loads and measured movement, with relevant observations and limitations. Confirm any particular submission format or intended recipient before the work is booked.

Where compression capacity is derived through an agreed assessment method rather than measured by a direct downward test, the report must identify the method and its assumptions. That is different evidence from a direct compression test; the designer determines whether it is suitable for the intended decision.

Acceptance criteria should be agreed in advance, so the results can be compared with the correct requirements. A test report describes the tested foundation element and test conditions. It does not certify the whole building, approve every screw position or replace the structural design and any required building-control decisions.

Coordinating testing with foundation work

For a new foundation, discuss testing while the screw layout and frame connections are being developed. That allows trial work, installation and any specified verification to fit the construction sequence. Monitoring insertion torque may support the installation record, but it is not an automatic substitute for the load tests required by the design.

Before the visit, agree how the work area will be made available and tell us about known buried services, restricted access or other work taking place. We will confirm any preparation needed once the test arrangement is understood. Initial photographs are helpful but a site description is enough to start.

If you also need the foundation installed, see Salisbury ground screw installation. A poured concrete base in Salisbury is another foundation option where the building needs a slab. You can discuss testing independently of either installation service.

Testing enquiries around Salisbury

Give us the site address when enquiring about testing in the Salisbury area, including the neighbourhoods and villages listed here. City and nearby SP1/SP2 addresses and surrounding SP3/SP4/SP5 enquiries are considered by postcode and test scope; the visit arrangements are confirmed for your particular site.

  • Salisbury neighbourhoods and immediate surroundings: city centre, Harnham, Bemerton, Bemerton Heath, Fisherton, Churchfields, St Paul's, Stratford-sub-Castle, Milford, Milford Hill, Petersfinger, Bishopdown, Bishopdown Farm, Hampton Park, Riverdown Park, Laverstock, Ford, Old Sarum and Longhedge.
  • Wilton and neighbouring villages: Wilton, Quidhampton, Netherhampton, Burcombe, South Newton, Stoford, Great Wishford, Stapleford, Steeple Langford, Barford St Martin, Compton Chamberlayne, Dinton and Fovant.
  • Woodford, Amesbury and nearby villages: Lower Woodford, Middle Woodford, Upper Woodford, Great Durnford, Little Durnford, Netton, Salterton, Newtown, Amesbury, Winterbourne Earls, Winterbourne Dauntsey, Winterbourne Gunner, Hurdcott, Porton, Idmiston, Gomeldon, Allington, Boscombe, Newton Toney and Cholderton.
  • Alderbury and adjoining villages: Alderbury, Whaddon, Pitton, Farley, Firsdown, Winterslow, East Grimstead, West Grimstead, West Dean and Whiteparish.
  • Britford, Downton and the southern villages: Britford, Odstock, Nunton, Bodenham, Downton, Charlton All Saints, Standlynch, Redlynch, Morgan's Vale, Woodfalls, Lover, Bohemia, Landford, Nomansland and Hamptworth.
  • Coombe Bissett and the Chalke villages: Coombe Bissett, Homington, Stratford Tony, Bishopstone, Broad Chalke, Bowerchalke and Ebbesbourne Wake.

Feedback on Craig’s earlier work

Feedback on Craig’s earlier groundwork and customer service.

"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
— Verified CustomerMyBuilder · SO · Cobble edge and gravel strip
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
— Verified CustomerCheckatrade · BH20 · Garage base

Ground screw testing questions

The right brief brings the design requirements and safe site arrangements together.

Can I book testing without buying ground screw installation?

Yes, standalone testing enquiries are welcome. That includes suitable trial screws and accessible existing screws installed by another contractor. We establish the purpose, screw information and safe test arrangement before confirming the scope, so the visit can produce evidence relevant to your project.

What can a trial screw tell my designer?

A trial can show the response of the selected screw at the test position under the agreed loading. It can inform decisions about the proposed foundation specification and further investigation. Your designer determines which locations are representative and what additional evidence is needed for the full layout.

How do I know which direction of test to request?

Begin with the force the foundation must resist and the decision the test should support. Pull testing examines uplift, compression testing downward load and lateral testing sideways response. If you are unsure, explain the project and we can discuss what information the designer needs to define the brief.

Will every screw need to be tested?

The number and distribution of test positions are set for the project rather than assumed from a standard package. Relevant considerations include the foundation design, available ground information, installation records and any variation across the site. Agree the sample and acceptance criteria with the responsible designer.

What information helps when another installer fitted the screws?

Send any screw product details, layout, installation date and installation or torque records you have. Photographs can help identify the visible connections and access. Missing paperwork can be discussed at the enquiry stage, although the final assessment may require information that testing alone cannot establish.

Can testing take place beneath an existing garden building?

It may be possible where the relevant screw and a safe loading arrangement are accessible. The building's current load and its connection to the foundation must be considered. Any temporary support, unloading or disconnection is agreed as enabling work; it should not be attempted simply to obtain a quote.

Does a pull result also count as a compression result?

An upward test directly measures uplift behaviour. If an agreed method uses that evidence to derive a compression assessment, the method, assumptions and applicability must be stated. When the project requires directly measured downward response, specify a direct compression test rather than treating the two records as identical.

Is installation torque monitoring the same as load testing?

No. Monitoring records the resistance to turning while the screw is being driven. A load test applies an agreed force to examine load and movement in the required direction. Any relationship between installation torque and capacity needs an applicable assessment method; there is no universal conversion for every screw and ground condition.

What does specialist torsional testing involve?

It is a separately scoped test that applies a twisting action and examines rotational response. It is distinct from observing torque during installation and from applying an upward, downward or sideways load. Specialist torsional testing and installation torque monitoring are both priced on application.

Who decides whether the measured response is acceptable?

The responsible designer or other appointed competent assessor sets the relevant criteria and interprets the evidence against the design. We record the agreed test and results so that assessment can be made. Clarifying the criteria before the visit avoids an ambiguous result with no agreed basis for comparison.

Can a tested screw remain part of the foundation?

That depends on the test purpose, loading level, observed movement and the designer's instructions. Some tests are intended as verification while others explore a limiting response. The test plan should say whether the screw may be retained and what review or replacement is required afterwards.

What will I receive after testing?

You receive the agreed written test record, identifying the tested positions and method with the recorded load and movement information and relevant observations. Tell us beforehand if a designer or approving body requires a particular format. The report supports foundation assessment; it is not certification of the complete building.

Do I need an engineer's document before I contact you?

No. Your first message can explain the project, why you need evidence and the postcode. We can then establish what technical requirements and site information are needed before booking. If a designer is already involved, their brief can be added to the discussion when available.

What happens if the result does not meet the agreed criteria?

The measured response and relevant observations are reported for the designer's review. They may call for a change to the screw specification or layout, further investigation or additional testing. Agree any revised design and follow-up scope before installation or loading continues on that basis.

What does each additional ground screw test cost?

At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type. The first test of each type is priced separately, using the starting price for your location. The extra-test charges stay the same in every location.

Arrange a Salisbury testing enquiry

Tell us why you need the test and where the screws are, and we can discuss the next step. Find the wider foundation offer on our Salisbury page and our Wiltshire service-area page.