Ground screw testing in Seaton
JustBases offers standalone ground screw testing in Seaton for suitable trial and existing supports, including another installer’s screws. We apply the agreed loading and record the response, supplying the results and a written report. Applicable project load calculations are included where agreed in the quotation.
Ground screw tests we offer
The force direction matters to the evidence obtained. We offer the three physical methods below and agree the required loading with the project’s test requirements. A request from your designer is helpful, but you can first enquire by explaining what the foundation supports and why you need testing.
Pull-out testing
An upward force is applied to investigate resistance to uplift. The response is recorded under the agreed loading at the test position. This supplies pull-out evidence for the screw and arrangement tested, to be considered against the project’s requirements.
Learn more: Pull-out testingCompression testing
A direct compression test applies downward loading and records how the screw responds. An applicable agreed calculation may also provide compression information from other evidence. Calculated values are identified as such, separately from a physical downward test result.
Learn more: Compression testingLateral testing
A lateral test applies a sideways force and measures the response in the specified direction. The loading and connection arrangement must suit that requirement. It is a physical horizontal test, distinct from upward, downward or twisting-load evidence.
Learn more: Lateral testingGround screw testing prices in Seaton
The physical-test guides are starting points for discussing the work. Your written quotation identifies the required test programme, positions and practical arrangements, together with any preparation included. Recorded results and a written report are part of the service. Any project calculations must have an applicable basis and be agreed in the scope.
Installation torque monitoring and specialist torsional testing are two separate price-on-application services. Monitoring records turning resistance during driving; a torsional test applies an agreed twisting load. Neither is automatically supplied with installation or a pull, compression or lateral test.
Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.
- Pull test (tensile or uplift test)
- From £514
- Load test (compression test)
- From £1,027
- Lateral test (sideways load)
- From £503
- Installation torque monitoring
- Price on application
- Specialist torsional load test
- Price on application
Each additional test
Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.
- Pull test (tensile or uplift test)
- £160 extra
- Load test (compression test)
- £320 extra
- Lateral test (sideways load)
- £155 extra
No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.
Ask about a ground screw test
Give us the postcode and the purpose of the proposed test. Tell us what is already on site or share an existing testing request; drawings, photographs and product details can be added when available.
Use this form, call 01202 039753 or message Craig on WhatsApp. We will discuss the appropriate service and the information needed to agree it.
Request your free quote
Explain what you need to find out from the screw foundation. Any existing request or screw information is helpful if available.
Your enquiry
Ground screw testing in Seaton
How ground screw testing works
Agreeing the test
The project’s intended assessment establishes the required loads, test positions and acceptance criteria. We clarify those requirements and define the work we can provide. The quoted commission identifies the test method and any agreed project load calculations before the visit is arranged.
Access and safe test arrangements
We establish a suitable arrangement for applying the load and recording the response. Access to the screw and connection, working space and any existing attached loads are considered.
Results and report
You receive the recorded test results and written report. Where project calculations have also been agreed, the method used is applicable to the evidence and requirements being assessed. Calculated values are distinguished from the physical measurements taken during testing.
Testing existing screws and trial installations
For a proposed foundation, a suitable trial can be tested to obtain the requested evidence. If you need a trial screw supplied or fitted as well, say so when enquiring.
When screws already carry a floor or building, explain what is attached and how the supports can be reached. The existing loads and connections affect what can safely be tested. Keep them intact while arrangements are assessed; any preparation that affects the structure needs a safe method and agreed responsibility.
What your test report tells you
The written report gives the results of the commissioned test for the foundation assessment. Your responsible designer or assessor uses that information against the required performance of the foundation. Approval of the complete design or building is a separate matter from receiving the test report.
Arranging testing in Seaton
The written scope and price are agreed before booking the work, with the site arrangements established for the test being commissioned.
Areas we cover around Seaton
We welcome enquiries in Seaton town centre and the Seaton Hole, Seaton Down Road, Seaton Down Hill, Harepath Hill, Harepath Road, Colyford Road, Beer Road, Harbour Road and The Underfleet areas.
Nearby communities include Beer, Branscombe, Southleigh, Northleigh, Farway, Netherton, Sallicombe and Woodbridge. You can also ask about work around Offwell, Wilmington, Widworthy and Honiton.
We consider projects in Colyford, Colyton, Whitford, Shute, Seaton Junction, Umborne and Hampton, together with Kilmington, Dalwood, Stockland and Axminster.
Other local enquiry areas include Axmouth, Dowlands, Stedcombe Vale, Boshill, Musbury, Combpyne and Rousdon.
Enquiries are also welcome from Weston, Salcombe Regis, Sidbury, Sidford and Sidmouth, as well as Uplyme and Lyme Regis.
EX12, EX24, EX13, EX14, EX10 and DT7 are district examples for the places listed. Send the full site postcode and the work required so we can confirm availability and allow for the arrangements and travel in your written quotation.
Feedback on Craig’s earlier work
Feedback on Craig’s earlier groundwork and customer service.
"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
Frequently asked questions
Can an owner or installer book testing without new installation?
Yes. Testing is available as its own commission for homeowners, installers and other project customers. Suitable existing screws can be considered even if another company supplied or fitted them.
How do I know which ground screw test I need?
Start by telling us what the screws support and why testing is being considered. We can discuss which test is relevant; you do not have to select one before contacting us. Any designer’s request you already have can help establish the required loading and test scope.
What does an uplift or pull-out test measure?
The screw is loaded upwards and its response recorded. That provides evidence of resistance to the agreed uplift loading at the tested position. The relevant project criteria determine how that response is assessed.
What evidence comes from direct compression testing?
It comes from physically pushing down on the screw under the specified loading and recording the resulting response. The recorded results are identified separately from a compression capacity obtained by calculation using other evidence.
How is a lateral test different?
It examines response to an applied horizontal force in the agreed direction. The screw connection and loading arrangement are part of the test requirements. This gives sideways-loading evidence, rather than the upward or downward response measured by axial tests or the twisting response of a torsional test.
When can compression be assessed by calculation?
A suitable method needs justification for the available evidence, relevant product and project information. Where applicable and commissioned, it can be used to calculate compression capacity, with the result labelled as calculated. It is not a direct downward test and there is no universal conversion from a pull result.
Who supplies the required loads and acceptance criteria?
They follow the responsible designer’s requirements or the project’s specified foundation assessment. We agree the testing against that intended use of the evidence.
When is insertion torque monitoring available?
The record is made as the screw is driven, so request it when the installation is being arranged. It measures turning resistance during that operation and is separately agreed, price on application. It provides different information from a later physical load test on an installed screw.
What does a specialist torsional test involve?
It applies a defined twisting load to investigate the rotational response required by the project. Its arrangement and purpose are agreed as a separate specialist commission, price on application. It is different from monitoring insertion resistance while driving, and is not automatically part of the other physical tests.
Can testing be discussed before the main foundation is ordered?
Yes. A suitable trial can be considered while the foundation proposal is being developed. The quotation defines the test and any separately required screw supply or fitting for that investigation.
Can a screw supporting an attached building be considered?
It can be assessed for a suitable safe test arrangement. Leave structural fixings and supports in place while enquiring; any preparation affecting the building must have an appropriate safe method agreed before it is undertaken.
What if the original installer information is incomplete?
Send the product identification, installation or support information you already have and explain what is on site. We can identify what else needs establishing to offer an appropriate test.
What written information will the service provide?
Recorded test results and a written report are supplied. Project load calculations are provided where agreed in the quotation and supported by an applicable method, with calculated evidence identified separately from measurements.
Can I ask for a price before a complete testing brief is issued?
Yes. Begin with the postcode and the reason you are considering testing. Any existing request, screw details or drawings can follow when available, with the requirements and safe arrangements agreed before attendance. At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type; the first test of each type is priced separately.
What happens next
We discuss why the evidence is needed and develop the test scope and written quotation. Once requirements and safe arrangements are agreed, the work can be scheduled. The service supplies your recorded results and written report, plus applicable calculations where commissioned.