Detail of an installed ground screw

Ground screw testing in Swanage

JustBases offers ground screw testing in Swanage as a standalone service, including suitable screws installed by other companies. Upward pull, direct compression and lateral tests investigate different loading directions, with recorded results and a written report for the agreed work.

Ground screw tests we offer

Tell us what the test needs to establish. Each physical method applies force in a particular direction and records the response under the agreed test arrangements. If you are unsure which method has been requested, send the information you have and we can discuss it.

Lateral testing

Sideways loading investigates response in the agreed horizontal direction. The test's connection and loading arrangement are established for the relevant requirement.

Learn more: Lateral testing

Ground screw testing prices in Swanage

The guides distinguish the physical test methods. Your written quotation will agree the actual testing work, including the required positions and loading programme, safe setup and any project-specific calculations requested alongside the normal results and written report.

Recorded installation-torque monitoring and specialist torsional testing are separate services, both price on application. Monitoring concerns resistance during insertion; torsional testing applies a deliberate twisting load under its own agreed test scope. Neither is automatically included with the physical tests.

Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.

Installation torque monitoring
Price on application
Specialist torsional load test
Price on application

Each additional test

Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.

Pull test (tensile or uplift test)
£160 extra
Load test (compression test)
£320 extra
Lateral test (sideways load)
£155 extra

No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.

Ask about a ground screw test

Start with the site postcode and the reason for the test. If someone has sent you a request, you can share it in its current form; an engineer's brief is not needed just to get in touch. Use the form, call 01202 039753 or send a WhatsApp message.

Request your free quote

What do you need to find out about the foundation? Tell us what you know so far and the site postcode.

Your enquiry

Ground screw testing in Swanage

Please provide either an email address or a phone number.

Add site photos, video or a drawing (optional)

Upload up to 5 photos or a short video of your site to help us provide an accurate quote.

0/5 files. JPG, PNG, WebP, PDF, MP4, MOV accepted — up to 100MB each.

Free, no-obligation quote. Your details are used to respond to this enquiry; see our privacy policy.

How ground screw testing works

The test needs a clear purpose and safe practical arrangement. We establish the relevant details before the visit, so the recorded evidence answers the agreed requirement.

Agreeing the test

The responsible project requirements establish the loading and acceptance criteria. We agree the method, positions and programme, together with any applicable calculations or other professional scope included in the quotation.

Access and safe test arrangements

We assess how the screw can be tested, including its head or connection, existing loading and the space needed for safe arrangements. Any preparation or structural support work is agreed before testing; structural connections should be left intact when making the initial enquiry.

Results and report

The response to the agreed loading is recorded and supplied with a written report. Where project-specific calculations are commissioned, their basis and calculated status are made clear alongside the test evidence.

Testing existing screws and trial installations

Let us know whether the foundation is still being planned or already carries a building. That stage affects how the test can be arranged and which support details need review. Testing can be ordered on its own, with any required trial-screw supply or fitting priced explicitly.

For an existing foundation, testing depends on a suitable accessible arrangement and the loads or connections already present. We can consider another installer's work, but need to assess how the required test can be performed safely. Leave structural connections in place while we discuss the proposal.

What your test report tells you

Your report identifies the agreed test and its recorded findings, such as the applied loading and measured movement. It gives the responsible project professional evidence to assess against the relevant requirement.

Any agreed compression calculation is identified as calculated, with its applicable method and basis stated. It is separate from a direct downward load test.

Arranging testing in Swanage

Tell us where the screws are and what stage the project has reached. We can discuss the requested evidence, confirm what information or site preparation is needed and agree the work and price before arranging a visit.

For new supports as well as a test, see Swanage ground screw installation for the foundation and frame options.

Areas we cover around Swanage

We welcome enquiries in Swanage, Durlston, Herston, Ulwell and New Swanage.

Around Langton Matravers, enquiries include Acton, Blacklands, Coombe, Knitson and the Knaveswell and Putlake localities. Nearby villages and areas include Harman's Cross, Worth Matravers, Kingston, Corfe Castle, Studland and Norden.

The surrounding catchment also includes Church Knowle, Furzebrook, Steeple, Kimmeridge and East Creech; and Wareham, Stoborough, Sandford, Arne, Ridge, Stoborough Green and Worgret.

You can also ask about a site in the Rempstone Estate/Forest area or around Godlingston Heath. Please identify the actual property or work location so that arrangements and any relevant permissions can be considered.

You can arrange standalone testing in BH19 or BH20 for suitable screws installed by JustBases or another contractor. Tell us what needs checking and what is already attached to the heads. We can discuss safe access to the connections and the report needed by the person assessing the foundation. See our Wareham page for that town or the Dorset service directory for other listed locations.

Feedback on Craig’s earlier work

Feedback on Craig’s earlier groundwork and customer service.

"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
— Verified CustomerMyBuilder · SO · Cobble edge and gravel strip
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
— Verified CustomerCheckatrade · BH20 · Garage base

Frequently asked questions

Can I order testing without buying an installation?

Yes. Testing is available separately for suitable trial or existing screws, including another company's installation. We first establish the purpose and whether the proposed screw and safe setup suit the required method. If supply, fitting or other preparatory work is also needed, that is identified separately in the quotation.

What if the request I received just says ground screw test?

Send us the request and tell us what the foundation is intended to support, along with the postcode. You do not have to interpret it or choose technical loads before contacting us. We can discuss which evidence is being sought, then agree the method and necessary project requirements with the relevant parties before testing.

What response does a pull-out test measure?

It records how the tested screw responds as an upward force is applied under the agreed procedure. The applied force and movement provide evidence relevant to uplift at that position and under those arrangements. The required loading and acceptable response are established for the project's purpose.

What is measured by a direct compression test?

A direct test applies downward loading and records the screw's movement or response. It provides physical evidence in that loading direction under the agreed setup. A compression figure calculated from other evidence is different: the report identifies it as calculated, rather than describing it as a direct downward test.

When is sideways loading the relevant test?

Ask about lateral testing when the required evidence concerns sideways force at a support. We agree which direction and connection level are to be loaded, then record the resulting movement. The written findings describe that setup so the responsible designer can relate them to the requirement.

Can compression information be calculated from pull evidence?

It can be considered where an applicable method and the relevant screw and project information support it. The calculation scope is agreed in the quotation and the resulting value is identified as derived. An upward result cannot simply be converted into a universal downward capacity for any screw or site.

Who establishes test loads and acceptable response?

The responsible designer or project requirement determines what loading and response need to be assessed. Those criteria, the chosen method and the relevant test positions are settled before the work. If you do not yet have a detailed instruction, explain the purpose when enquiring so the requirements can be developed with the appropriate party.

What results and report do I receive?

You receive recorded test results and a written report for the agreed work. The findings identify the relevant measurements and test context. Project-specific calculations are included where applicable and agreed in the quotation, with calculated output distinguished from physical measurements. Additional design or approval work is not automatically part of a testing order.

Can a trial be tested before the full foundation is installed?

Yes, a suitable trial installation can be considered when early evidence is needed for the foundation proposal. Agree the intended purpose, product and testing arrangement before it is installed, including any supply or fitting you want quoted. The findings relate to that trial and inform the responsible assessment of their relevance to the planned work.

Can screws beneath an existing building be considered?

They can be assessed, but the existing loads, connections and access influence whether the requested test can be undertaken safely. Any necessary preparation or temporary support must be properly agreed by the relevant parties. Do not disconnect the frame or disturb a structural connection just to provide information for an enquiry.

What if I do not have complete installation records?

Tell us what is available and what you need to establish. Product information, an installer's details or safely obtained photographs may help identify the foundation. We can explain what further information is needed to assess a suitable test; missing records need not stop an initial discussion, although the test itself requires enough information and safe arrangements.

How is insertion-torque monitoring arranged?

It needs to be agreed as resistance recording during screw insertion, so it should be discussed before that work takes place. It is separately quoted on a price-on-application basis. The monitoring scope identifies the installation information to be recorded for the project.

What is specialist torsional testing?

It investigates response to an applied rotational or twisting load under an agreed test scope. This differs from monitoring resistance during installation and from the upward, downward or sideways physical tests. Specialist torsional testing has its own price-on-application quotation and is not automatically included when another method is ordered.

Does testing approve the whole building?

No. The results and report provide evidence for the responsible professional's assessment of the relevant foundation requirement. They do not automatically certify every screw, frame connection or the complete structure. The agreed scope should identify any additional calculations or professional work required; the installation guarantee is not a warranty of testing results or of the building.

What does each additional ground screw test cost?

At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type. The first test of each type is priced separately, using the starting price for your location. The extra-test charges stay the same in every location.

What happens next

We will discuss the purpose, develop the test scope and provide a written price. Once the requirements and safe arrangements are agreed, the test can be scheduled, followed by your recorded results and written report. Start a testing enquiry, call 01202 039753 or use WhatsApp.