Detail of an installed ground screw

Ground screw testing in Wokingham

JustBases offers standalone ground screw testing in Wokingham: pull-out, direct compression and lateral tests for an agreed foundation requirement. We can assess trial screws and suitable existing installations, including another company's work. You do not need to buy an installation from us; tell us the site postcode and what you need to find out.

Ground screw tests we offer

A physical test applies a force in an agreed direction and records how the screw responds. That can help your project team assess a proposed foundation or investigate suitable supports already fitted. The question being asked determines the test: an upward result, a downward result and a sideways result are not the same information.

We discuss the screw, test positions, loading and required records before attendance. If an engineer or building supplier has requested evidence, send that request. If you have not reached that stage, describe the building and the reason for testing in ordinary terms; the detailed requirement can be established before a visit is booked.

Pull-out testing

An upward force is applied to investigate resistance to tension or uplift under the agreed test conditions. This may be the evidence requested where the foundation design needs to resist lifting forces. The report identifies what was tested rather than treating the result as a rating for every screw on the site.

Learn more: Pull-out testing

Direct compression testing

A direct downward load is applied and the screw's movement is recorded. It provides a physical compression result for the agreed screw and position. Where a separate compression calculation uses pull-test evidence, it must be identified as a calculation, not described as a direct downward test.

Learn more: Direct compression testing

Lateral testing

A sideways load examines the screw's lateral response. The connection, direction of loading and safe working space need to be agreed for the test. It answers a different question from a vertical pull or compression test and should be specified where that sideways evidence is needed.

Learn more: Lateral testing

Ground screw testing prices in Wokingham

The guide lists starting prices for the three main test directions. They are testing prices, separate from buying and installing a screw foundation. The written quotation confirms the method, number and arrangement of tests, reporting and travel for your Wokingham-area site.

Installation torque monitoring and specialist torsional testing are separate, price-on-application scopes. Monitoring records turning resistance while screws are installed; a torsional test examines the response to an agreed twisting force. Tell us what has actually been requested so the quote covers the right work rather than relying on the word 'torque' alone.

Local guide prices start with our Ringwood prices, adding 0.1% for each one-way road mile to the town, then rounding up to a whole pound. Your written quotation confirms the price for your site and agreed work.

Installation torque monitoring
Price on application
Specialist torsional load test
Price on application

Each additional test

Each extra charge applies to an additional test of the same type, at the same location on the same day. The first test of each type is priced separately.

Pull test (tensile or uplift test)
£160 extra
Load test (compression test)
£320 extra
Lateral test (sideways load)
£155 extra

No VAT is added to the guide prices shown. Guide prices are subject to site conditions, access and the written quotation.

Ask about a ground screw test

Send the postcode and a short description of the project. Tell us whether you are selecting a screw, planning a trial or asking about an existing foundation. If you know which test is needed, name it; if not, explain the concern or pass on the request you have received.

Product details, an installation record, photos or a designer's instructions can help if already available. None needs to be assembled into a complete pack before you contact us. Use this form, call 01202 039753 or message Craig on WhatsApp, and leave any structural fixings or coverings undisturbed until a safe arrangement has been agreed.

Request your free quote

Give us your contact details and a short description of the testing you need. You can ask before the technical requirements are complete.

Your enquiry

Ground screw testing in Wokingham

Please provide either an email address or a phone number.

Add site photos, video or a drawing (optional)

Upload up to 5 photos or a short video of your site to help us provide an accurate quote.

0/5 files. JPG, PNG, WebP, PDF, MP4, MOV accepted — up to 100MB each.

Free, no-obligation quote. Your details are used to respond to this enquiry; see our privacy policy.

How ground screw testing works

A useful test answers the project's actual question and relates the results to a known screw and position. We agree what will be tested and how the results will be used before setting up the equipment, including any requirements already provided by the building supplier or designer.

The arrangements also need to suit the site. Existing frames, nearby structures, slopes and the available working space can affect the connection and equipment setup. Establishing those details in advance helps us plan the right equipment and safe working arrangements for the visit.

Agree the testing brief

We establish the force direction, screw details, test locations and reporting requirement. Target loading, acceptance and stopping criteria are settled with the responsible project team. Where a designer is involved, their requirements should be included rather than inferred from a general product figure.

Plan access and the test arrangement

We assess how equipment can reach the positions and connect safely, including the space needed to apply and react the load. Any proposed access changes or work around an existing structure must be agreed before testing; the customer should not loosen a loaded connection to make it accessible.

Record the results and provide the report

The agreed test is carried out and the applied loading and response recorded as required by the brief. We provide recorded results, a written report and the agreed project load calculations. The report scope and any separate review or approval requirements are established for the job.

Testing existing screws and trial installations

Testing can be discussed before a complete foundation has been installed. A trial screw and chosen position can provide evidence to inform the design, with the product, installation and intended test agreed first. The project team needs to consider which positions are representative and whether more than one result is required; a single convenient location should not automatically stand for the whole footprint.

For existing screws, send whatever product and installation information you already hold and explain what is attached to them. A clear photo of an accessible head or connection is helpful, but an obscured head does not mean you should dismantle the frame for an enquiry. We first need to establish whether the connection, working room and structural situation allow an appropriate test.

The loading programme and what happens to the tested screw afterwards are also part of the scope. A test to a specified load and a test exploring a limiting response serve different purposes. Continued use, further assessment or replacement should be agreed for that foundation, not assumed from the fact that testing has taken place.

What your test report tells you

The report relates the recorded results to the agreed screws, positions and testing carried out. The loading and measured response need to be identifiable, with the calculation scope settled in the quotation. Tell us before the visit if the building supplier, designer or approval body requires a particular form of information.

Keep measured and calculated figures distinct. A direct compression test records a screw being loaded downwards. An agreed calculation using pull-test results is a separate assessment and is described as such. Neither type of vertical evidence should be presented as a physical sideways test.

The responsible designer considers the findings within the complete foundation and building design, including frames, connections and the relevant loads. A test report is not automatic certification of the whole structure, an engineer-signed report or Building Control approval. Any additional professional review or approval requirement needs to be agreed separately.

Arranging testing in Wokingham

Give us the full site postcode, the test address and a contact for access. Say where a vehicle could stop and describe the route to the screws, especially where it includes steps, tight turns or a shared passage. These details help us plan the visit and the equipment route.

Coordinate the test with the building sequence where possible. If a frame or decking is about to cover the heads, mention that timing before it happens; access to the required connection and space around it still need assessment. Do not delay the first enquiry while collecting every drawing, but allow the test arrangements to be agreed before committing dependent work.

For neighbouring places, see Berkshire service areas and Reading ground screw testing. If you also need a foundation installed, the separate Wokingham installation guide explains that service. Testing remains available on its own, and the Wokingham overview brings the local services together.

Areas we cover around Wokingham

We welcome enquiries from Wokingham town centre and the surrounding neighbourhoods of Emmbrook, Woosehill, Norreys, Bean Oak, Keephatch, Matthewsgreen, Montague Park, Evendons, Wescott, Eastheath and Dowlesgreen.

The nearby enquiry area includes Winnersh and Sindlesham; Barkham, Arborfield Cross and Arborfield Green; Finchampstead and California; Hurst; and Wokingham Without through Chapel Green, Holme Green, Gardeners Green, Heathlands and Pinewood towards Crowthorne. Send the full site postcode so we can confirm the service, travel and visit arrangements for your address.

We take enquiries across the local RG40 and RG41 postcode districts, as well as nearby RG2 addresses around Arborfield, RG10 around Hurst and RG45 around Crowthorne. Work and travel are confirmed for the individual address. For testing at another postcode, send the location and purpose so the practical arrangements can be checked.

Feedback on Craig’s earlier work

Feedback on Craig’s earlier groundwork and customer service.

"Craig and the team are absolutely fantastic. From courtesy, to standard of work, to tidiness — everything exceeded expectations. The job was arranged, booked and done extremely quickly and we are very happy with the results. Nothing was too much trouble, and communication was easy."
— Verified CustomerMyBuilder · SO · Cobble edge and gravel strip
"Craig and his crew were excellent from the first communication, quote, timing of work and quality of work. Highly recommended."
— Verified CustomerCheckatrade · BH20 · Garage base

Frequently asked questions

These answers explain testing as a separate service, from an early enquiry through to the results and their use by your project team.

Can I arrange testing without purchasing ground screws from JustBases?

Yes. Testing is offered as a standalone service, including enquiries involving another supplier's or installer's screws. We assess the product, available information, connection and site arrangements before agreeing what can be tested. Tell us the purpose and postcode first; a new foundation purchase is not part of the entry requirement.

Which test should I request if I do not have an engineer's brief?

Describe the building and what you are trying to establish, or send the question raised by your supplier. We can explain the different testing directions and what information is needed to agree the scope. The detailed loading and acceptance requirements must be settled before testing, but you can make an initial enquiry without having already commissioned a complete brief.

What does an uplift or pull-out test measure?

An upward force is applied to the agreed screw, with its response recorded under the specified conditions. It provides evidence about that upward loading case at the tested position. It is not a measurement of every force acting on the complete building, so the required test direction and its intended use need to be clear.

Is direct compression testing different from calculating compression from a pull result?

Yes. Direct compression physically pushes down on the screw and records the response. A compression figure calculated from pull-test evidence uses an agreed assessment method and relevant project information; it is reported as a calculation. There is no universal conversion that makes any upward test equivalent to a direct downward measurement.

When would a sideways test be needed?

A designer may require lateral evidence where the structure transfers sideways forces into the supports. The necessary direction, loading and connection are agreed for that design. A lateral test applies force in the direction being investigated and records the screw's response, providing the sideways evidence needed by the project team.

Can installation torque be recorded after the screws have been fitted?

An installation torque record concerns the turning resistance measured while the screw is being installed. If that record is required, discuss monitoring when the installation is planned. A later specialist twisting test is a different service, with its own method and scope; it should not be presented as a recreation of an unrecorded installation log.

What is specialist torsional testing?

It examines the screw's response to an agreed twisting load. That differs from observing resistance during installation and from applying upward, downward or sideways force. Share the actual request so we can review the screw details, connection and access. The service is quoted individually rather than priced as one of the standard vertical or lateral tests.

Can a trial screw be tested before the full foundation is ordered?

Yes, that can be discussed as an early project stage. The screw, installation, test positions and required evidence need to be agreed so the result is relevant to the proposed foundation. Your project team should decide how the trial informs the design and whether additional positions are needed, rather than assuming one result clears every support.

What if the existing screw heads are covered by a timber frame?

Explain what is attached and send photos of what is already visible, if safe to obtain. We need to assess access to a suitable connection and the space for the equipment. Do not loosen frame fixings or remove a loaded structural part for an enquiry. Any necessary access work and structural precautions must be agreed first.

Does a load test necessarily pull out or damage the screw?

Not every test is intended to reach a limiting response, but the possible effect must be considered. A test to a specified load and an investigation of ultimate behaviour have different purposes and stopping criteria. We agree the purpose, loading programme and stopping criteria with your project team, including the treatment or continued use of the tested screw afterwards.

Who sets the test loads and decides whether the result is acceptable?

The required loading and acceptance criteria belong to the project's responsible design and assessment process. We agree them with the relevant project team before carrying out the test. You can still contact us before those details are ready; the first conversation helps identify the information and decisions needed for an appropriate testing brief.

What will I receive after the test?

The service provides recorded test results, a written report and the agreed project load calculations. The quotation establishes which tests and reporting are included. If a designer or approval body needs particular records, formatting or additional review, raise that before the visit so the reporting scope can be agreed rather than assumed afterwards.

Will the report approve my whole building foundation?

No. It records and assesses the agreed testing; the complete design also includes the other supports, frame, connections and building loads. An engineer's signature or approval certificate is not automatically supplied. The responsible designer and any approval body review the information within their own requirements, and a report alone does not grant Building Control approval.

How is a Wokingham testing visit priced and arranged?

Start with the full site postcode, test purpose and whether the screws are proposed or installed. We consider the method, number of tests, connection and access arrangements, travel and report requirements, then confirm the agreed price in writing. Let us know about any dependent building work so a suitable visit can be arranged before those connections become harder to reach. At the same location on the same day, each additional compression test costs £320 extra, each additional pull, tensile or uplift test costs £160 extra, and each additional lateral test costs £155 extra. These fixed charges are for further tests of the same type; the first test of each type is priced separately.

What happens next

Tell Craig the postcode, the project and why testing is needed. We discuss a suitable test arrangement, agree the scope and written price, then arrange the visit and reporting. You can start without a finished design and without buying an installation from JustBases.